ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS
PROCEDURE
CAUTION:
Electrostatic discharge can affect electronic
components. Take precautions during furnace installation
and servicing to protect the furnace electronic control.
Precautions will prevent electrostatic discharges from
personnel and hand tools which are held during the
procedure. These precautions will help to avoid exposing
the control to electrostatic discharge by putting the
furnace, the control, and the person at the same electro-
static potential.
1. Disconnect all power to the furnace. DO NOT TOUCH
THE CONTROL OR ANY WIRE CONNECTED TO THE
CONTROL PRIOR TO DISCHARGING YOUR BODY’S
ELECTROSTATIC CHARGE TO GROUND.
2. Firmly touch a clean, unpainted, metal surface of the
furnace chassis which is close to the control. Tools held in
a person’s hand during grounding will be satisfactorily
discharged.
3. After touching the chassis you may proceed to service the
control or connecting wires as long as you do nothing that
recharges your body with static electricity (for example; DO
NOT move or shuffle your feet, DO NOT touch un-
grounded objects, etc.).
TABLE 1—DIMENSIONS (IN.)
UNIT SIZE
A
D
E
VENT CONN
SHIP. WT (LB)
024045
14-3/16
12-9/16
12-11/16
4
118
036045
14-3/16
12-9/16
12-11/16
4
120
024070
14-3/16
12-9/16
12-11/16
4
142
036070
14-3/16
12-9/16
12-11/16
4
127
042091
17-1/2
15-7/8
16
4
124
048091
21
19-3/8
19-1/2
4
155
036110
17-1/2
15-7/8
16
4
153
048111
21
19-3/8
19-1/2
4
173
060111
24-1/2
22-7/8
23
4
176
048135
21
19-3/8
19-1/2
5*
173
060135
24-1/2
22-7/8
23
5*
187
060155
24-1/2
22-7/8
23
5*
194
* Oval collar
→
Fig. 1—Dimensional Drawing
A00210
A
D
13
⁄
16
″
E
11
⁄
16
″
11
⁄
16
″
28
1
⁄
2
″
39
7
⁄
8
″
24
5
⁄
16
″
11
⁄
16
″
3
″
2
1
⁄
16
″
1
″
12
5
⁄
16
″
5
3
⁄
8
″
5
13
⁄
16
″
2
3
⁄
8
″
AIR INLET
7
⁄
8
-IN. DIA HOLE
POWER ENTRY
7
⁄
8
-IN. DIA
ACCESSORY
1
3
⁄
4
-IN.
DIA HOLE
GAS ENTRY
1
⁄
2
-IN. DIA HOLE
THERMOSTAT
WIRE ENTRY
SIDE INLET
VENT CONN
1. Two additional
7
⁄
8
-
in. dia holes are located in the top plate.
2. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer's recommendations for equivalent diameters.
a. For 800 CFM–16-in. round or 14
1
⁄
2
x 12-in. rectangle.
b. For 1200 CFM–20-in. round or 14
1
⁄
2
x 19
1
⁄
2
-in. rectangle.
c. For 1600 CFM–22-in. round or 14
1
⁄
2
x 23
1
⁄
4
-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific
use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the
bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
NOTES:
5
3
⁄
8
″
5
13
⁄
16
″
2
3
⁄
8
″
2
11
⁄
16
″
1
″
2
1
⁄
16
″
19
″
13
⁄
16
″
7
⁄
8
-IN.
DIA
POWER ENTRY
AIRFLOW
OUTLET
1
1
⁄
2
-IN.
DIA
R.H. GAS ENTRY
7
⁄
8
-IN. DIA ACCESSORY
1
⁄
2
-IN. DIA THERMOSTAT
WIRE ENTRY
SIDE INLET
14
1
⁄
2
″
1
″
23
1
⁄
4
″
SIDE RETURN
DUCT LOCATION
1
1
⁄
4
″
TYP 1
″
5
⁄
8
″
TYP
—2—
Содержание GAS-FIRED INDUCED-COMBUSTION FURNACES 383KAV
Страница 19: ...19...