background image

Fig.

13—Wiring

Diagram

A95285

PCB

BL

OWER

 O

FF 

DE

LAY

SE

LEC

T

IO

N CH

AR

T

90

SEC

135

SEC

180

SEC

225

SEC

GVR

H

I/L

O

RE

L

A

Y

SE

C-

1

SE

C-

2

PL

1

3

2

1

6

5

4

9

87

LE

D

TEST/TWIN

BL

OWER

OF

F

DE

LAY

G

R

Y

W

C

HU

M

HS

IR

ID

R

B

L

W

R

BL

OWER

SP

EED

SE

LEC

T

FU

1

C

OOL

HE

AT

L2

PL

3

PL

2

VA

C

120

L1

PR

1

1

2

1

2

3

PR

2

24 VA

C-

3A

FU

SE

SP

AR

E-

2

SP

AR

E-

1

EA

C-

1

EA

C-

2

C

1.5 A

MP

12

PL

5

WHT

BL

K

WHT

WHT

BLK

BLK

HS

I

BL

K

WHT

WHT   

(C

OM

)

RE

D  

 (

L

O)

BL

(M

ED

 LO

)

NO

TE

 #8

OL

ST

ART

BL

W

M

YE

L (

M

ED

 H

I)

BL

 (

H

I)

BR

N

BR

N

TRAN

BL

U

RE

D

BL

K

WHT

WHT (

C

OM

)

GR

N

CA

P

GR

N

2-

C

RE

D

FS

E

NO

TE

 #5

1-

M

3-

P

GV

FR

S2

BL

U

YE

L

RE

D

NO

TE

  

#

6

LS

RE

D

OR

N

PR

S

(W

HE

N US

E

D

)

LGPS

F

U

S

E

D

 DI

SC

ON

NE

C

T

SWI

T

CH

 (

W

HE

N REQ

’D

)

NO

TE

 #4

FU

2

BL

K

WH

T

GR

N

GR

N

JB

LEGEND

AL

S

A

U

X

IL

IA

RY

 LI

M

IT 

SWI

T

CH

OV

ER

TEM

P

. -

M

ANU

A

RE

SET

SPS

T-

(N

.C

.)

BL

W

R

BL

OWER

 M

O

TOR

 R

E

LA

Y,

 SP

ST-

(N

.O

.)

BL

W

M

BL

OWER

 M

O

TOR

C

A

P

C

AP

AC

IT

O

R

CP

U

M

IC

RO

PRO

C

E

S

S

O

R

 AN

CI

RC

UI

TRY

D

S

S

D

RA

F

T

 SA

F

E

G

U

A

R

D SW

IT

CH

EA

C-

1

E

L

E

CT

RO

NI

C AIR

 C

L

EA

NE

R CO

NNE

CTI

O

N (115

 V

A

C 1.

A

M

P

 M

A

X

.)

EA

C-

2

E

L

E

CT

RO

NI

C AIR

 C

L

EA

NE

R CO

NNE

CTI

O

N (C

OM

MO

N)

FR

S

F

LA

ME

 R

O

LL

OU

T S

W

-M

AN

UA

L R

ESE

T,

 S

PST-

(N

.C

.)

F

S

E

F

LAM

E

 PR

OV

IN

G ELE

C

T

R

OD

E

FU

1

F

U

SE,

 3 

A

M

P

, AU

TOM

O

TIV

E

 BLAD

E TYP

E

FA

CTO

R

Y

 I

N

S

T

ALL

E

D

F

U

2

F

US

E

 OR

 C

IR

C

U

IT

 BR

E

A

K

E

R

 CU

RR

E

N

T

 I

N

T

E

RR

UP

T

 D

E

VI

CE

(F

IE

LD I

N

ST

ALLE

D & 

S

U

P

P

LI

ED)

G

V

G

AS VA

LVE-

R

E

DU

ND

ANT

 O

PER

ATO

R

S

G

V

R

G

AS VA

LVE RE

LAY

, DP

ST-

(N

.O

.)

HI

/L

O

B

L

O

WER

 M

O

TOR

 S

PEE

D CH

ANG

E

 RE

LAY

, SPD

T

HS

I

H

OT SU

RFA

C

E I

G

N

ITOR

 (

115 VAC

)

HS

IR

HO

T SU

RFA

C

E I

G

N

ITO

R RE

LAY

, SPS

T-

(N

.O

.)

HU

M

24V

AC 

HU

M

ID

IFI

ER

 C

O

N

N

EC

TI

ON

 (

.5

 A

M

P

MA

X.

)

ID

M

INDU

CE

D DRA

FT MO

TO

R

ID

R

INDU

CE

D DRA

FT RE

LAY

, SPS

T-

(N

.O

.)

IL

K

B

LO

W

E

R AC

CE

S

S

 PA

N

E

L

 IN

TE

R

L

O

C

K

 SW

IT

CH

, SP

ST

-(

N

.O.

)

JB

JU

NC

TI

ON

 B

O

X

LE

D

L

IG

H

T

-E

M

ITT

IN

G DI

OD

E FOR

 S

T

AT

US CO

DE

S

LG

PS

LO

W G

AS 

PR

ES

SUR

E

 SWIT

CH

SPS

T-

(N

.O

.)

LS

LI

MI

T SWI

T

CH

, AU

TO RE

SET

, SPS

T(

N.

C.

)

O

L

AU

TO

-R

ESE

T IN

TER

N

AL M

O

TO

R O

VER

LOA

D

 TEM

P

. SW.

P

C

B

P

RI

NT

E

D

 CI

RC

UI

T

 B

O

A

R

D

P

L

1

9

-C

IR

CU

IT

 CO

NN

EC

T

O

R

P

L

2

2

-C

IR

CU

IT

 PC

B CO

NN

E

C

T

O

R

P

L

3

3

-C

IR

CU

IT

 ID

M C

O

N

N

E

C

T

O

R

PL5

2

-C

IR

C

U

IT

 H

S

I/

P

C

B CO

NN

EC

TOR

PR

S

P

R

ESS

UR

E S

W

ITC

H

, S

PST

-(

N.

O

.)

TE

ST/

T

W

IN

C

O

M

PO

NEN

T

 TEST

 & TW

IN

 TER

MI

NA

L

TR

AN

TR

ANS

F

O

R

M

E

R-115V

AC/

24VA

C

JU

NC

TI

ON

UN

M

A

RK

ED TE

RM

IN

AL

PC

B TER

MI

NA

L

FA

CTO

R

Y

 WI

RI

NG

 (115VA

C

)

FA

CTO

R

Y

 W

IRI

NG

 (

24VA

C

)

FI

ELD

 WI

RI

NG

 (115VA

C

)

FI

ELD

 W

IRI

NG

 (

24VA

C

)

CO

ND

UC

TO

ON

 PC

B

FI

ELD

 W

IRI

NG

 TE

RM

IN

AL

F

IE

L

D GR

OU

ND

EQ

UI

PM

EN

T G

R

O

U

N

D

FI

ELD

 SP

LIC

E

PLU

G

 RE

CEP

TAC

LE

L1

NE

UTR

A

L

L1

BLW

R

H

I/L

O

TO 11

5VAC FI

E

L

D DI

SCONNECT

NOTE #4

EQ

UI

PM

EN

T G

R

O

U

N

D

SP

ARE

-1

HE

AT

SP

ARE

-2

C

OOL

NO

TE

 #8

CO

M

HS

IR

EA

C-

1

ST

ART

OL

CO

M

HI

M

E

D HI

ME

D

 L

O

LO

BLW

M

SCH

E

MATIC DIA

G

R

A

M

(NAT

URAL GAS &

 P

R

OPANE

)

EA

C-

2

1

1

HS

I

2

PL5

2

PL2

3

PL3

PR

2

115V

AC

PR

1

TR

AN

24VA

C

1

2

ID

R

T

E

S

T

/T

WIN

FU

1

NO

TE

 #7

CA

P

L2

FR

S1

LG

PS

NO

TE

 #6

PL1

GV

2-C

1-M

3-P

NO

TE

 #5

8

FS

E

9

6

5

CP

U

HS

IR

ID

R

BLW

R

Y

G

C

R

W

GV

R

-2

SE

C-

1

H

I/L

O

GV

R

GV

R

-1

SE

C-

2

NOT

ES:

32

2858

-101

 REV. A

1.

IF A

N

Y

 OF THE O

R

IG

INAL

 EQUIP

M

E

N

T W

IRE 

IS REP

L

ACE

D

 U

S

E W

IRE RATE

D

 F

O

R

 105

°C.

2

.

INDUC

E

R

 (

ID

M

) AND BLOWER (BL

W

M)

 MOTORS

 CONT

A

IN I

N

TERNAL AUTO-R

E

SET THERMAL

OV

ERLOA

D

 SWI

T

C

H

ES

 (OL).

3.

BL

OW

ER M

O

TOR SPE

ED SE

LECTIONS

 ARE FOR A

VERA

G

E CONDITIONS,

 SEE

 INSTAL

LA

T

ION

IN

STRUCT

IONS FOR DETA

IL

S

 ON OPTIM

U

M SP

EED SE

L

E

CTI

O

N

.

4.

USE 

ONLY 

C

O

PPER W

IRE 

BETW

EEN THE DIS

C

ONN

E

C

T

 SWI

T

C

H

 A

N

D THE 

FU

RNACE

JU

N

C

T

ION

 B

O

(J

B)

.

5

.

THI

S

 WI

RE 

M

U

ST B

E

 CONNECTED TO FURNACE S

H

E

E

TMETAL FOR CONTR

O

L

 TO DE

T

E

CT

F

L

AM

E.

6.

FACTORY CONNECTED W

H

EN LG

PS NOT 

U

S

ED.

7.

REPL

ACE O

N

L

Y

 W

ITH A 

3 AM

FU

S

E

.

8.

YE

LLO

W L

EAD NOT 

ON ALL

 M

O

TORS.

9.

BL

OW

ER-

O

N

 D

E

LAY

, GA

S HEATI

N

G

 45

 SECONDS,

 COOLI

N

G

 OR HEAT P

U

MP

 2 S

E

CONDS.

10

.

B

L

O

W

E

R

-O

F

F

 DE

LAY

, GA

S H

EAT

IN

G

 90

, 13

5, 

180

 OR

 2

25 

SEC

ON

D

S

CO

OLIN

OR

 H

EAT

PUMP 90

 S

E

CONDS.

 (1

35

 S

E

CONDS ONL

Y

 ON S

O

M

E

 MODEL

S

)

1

1

.

IGNI

T

ION-

LOCKOUT WI

L

L

 OCCU

R A

FTER FOUR CONSECUTI

VE 

U

N

S

U

CCES

S

FUL

TRI

A

LS-FOR-

IG

N

ITI

O

N.

 CONTROL

 WI

LL

 A

U

TO-RES

E

T AFTER THREE 

H

O

U

R

S

.

12

.

W

HE

US

ED

 AU

X

ILIA

R

Y

 LI

MIT

 SWI

T

CH

 (

A

L

S

) IS 

ON

 D

O

WN

F

L

OW 

MOD

E

LS O

N

L

Y

.

1

3

.

S

OM

E M

O

D

E

L

S

 M

A

Y

 H

A

VE

 S

P

A

D

E

 Q

U

IC

K C

O

N

N

EC

T

 T

E

R

M

IN

AL

S

.

BLK

OM

SW

2

SW

1

OM

2

3

4

7

1

OM

HU

M

DS

S

AL

S

(W

HE

N US

E

D

)

(W

HE

N US

E

D

)

ID

M

IL

K

FR

S2

DS

S

ALS

PR

S

(W

HEN

 U

SED

)

(W

HEN

 U

SED

)

IL

K

NOTE

 #12

L1

NE

UTR

A

L

ID

M

(W

HEN

 U

SED

)

NO

TE

 #12

LS

WH

T

FR

S1

NO

T US

ED

NO

T US

ED

NO

T US

ED

(N

OT

 ON

 A

L

L

 MO

DE

L

S

)

SE

N

O

T

E

 #10

NO

TE

 #13

—11—

Содержание GAS-FIRED INDUCED-COMBUSTION FURNACES 373LAV

Страница 1: ...safety codes In the United States follow all safety codes including the National Fuel Gas Code NFGC NFPA No 54 1992 ANSI Z223 1 1992 In Canada refer to the current edition of the National Standard of...

Страница 2: ...during the procedure These precautions will help to avoid exposing the control to electrostatic discharge by putting the furnace the control and the person at the same electro static potential 1 Disc...

Страница 3: ...n fire electrical shock or other conditions which may cause personal injury loss of life or property damage Consult a qualified installer service agency local gas supplier or your distributor or branc...

Страница 4: ...an equal or greater amount of air is supplied to the room B Confined Space A confined space has volume less than 50 cu ft per 1000 Btuh of the total input ratings of all appliances installed in that...

Страница 5: ...OUTDOORS 1 SQ IN PER 4000 BTUH RETURN AIR VENT THROUGH ROOF CATEGORY I D B A C E 1 SQ IN PER 4000 BTUH DUCT TO OUTDOORS SUPPLY AIR 1 SQ IN PER 2000 BTUH DUCTS TO OUTSIDE 12 MAX 12 MAX CONFINED SPACE 1...

Страница 6: ...red length 1 X 3 8 in flat washer 3 8 in lockwasher and 3 8 in nut Dimples are provided for hole locations See Fig 1 Since horizontal crawlspace installation is very similar to the attic installation...

Страница 7: ...ent trap in the riser leading to the furnace The trap can be installed by connecting a tee to the riser leading from the furnace Connect a capped nipple into the lower end of the tee The capped nipple...

Страница 8: ...nergized with 115v 1 5 amp maximum during blower motor operation 2 Humidifier HUM Quick connect terminal HUM and screw terminal Com are provided for 24 v humidifier connection The terminals are energi...

Страница 9: ...FIELD SUPPLIED FUSED DISCONNECT CONDENSING UNIT TWO WIRE FURNACE R G C W C R G Y GND GND FIELD 24 VOLT WIRING FIELD 115 208 230 460 VOLT WIRING FACTORY 24 VOLT WIRING FACTORY 115 VOLT WIRING 208 230...

Страница 10: ...satisfied R G and R Y circuits are broken Furnace blower and EAC continue operating on cooling speed for an additional 90 sec 3 Continuous blower mode NOTE EAC 1 terminal is energized with 115v whene...

Страница 11: ...ESSURE SWITCH SPST N O TEST TWIN COMPONENT TEST TWIN TERMINAL TRAN TRANSFORMER 115VAC 24VAC JUNCTION UNMARKED TERMINAL PCB TERMINAL FACTORY WIRING 115VAC FACTORY WIRING 24VAC FIELD WIRING 115VAC FIELD...

Страница 12: ...Specific gravity 0 58 Therefore Orifice No 44 Manifold pressure 3 6 in wc The furnace is shipped with No 43 orifices Therefore in this example all main burner orifices must be changed and the manifold...

Страница 13: ...9 3 4 3 7 3 2 40 41 39 3 5 3 8 3 3 40 38 39 3 6 3 2 3 4 40 38 39 3 8 3 3 3 5 38 39 3 4 3 6 38 39 3 4 3 7 890 41 42 3 2 3 6 41 42 3 4 3 7 40 41 3 2 3 5 40 41 3 3 3 6 40 41 39 3 4 3 7 3 2 40 41 39 3 5 3...

Страница 14: ...nd operates if there is a motor failure TABLE 8 GAS RATE CU FT HR SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL SECONDS FOR 1 REVOLUTION SIZE OF TEST DIAL 1 cu ft 2 cu ft 5 cu ft 1 cu ft 2 cu ft 5 cu ft...

Страница 15: ...n properly and correct condition e Turn off 115 v power to furnace f Reconnect inducer motor wires replace control door and turn on 115 v power to furnace 4 Check auxiliary limits when used a Turn off...

Страница 16: ...ing popular video based formats and materials All include video and or slides plus companion book Classroom Service Training plus hands on the products in our labs can mean increased confidence that r...

Отзывы: