3

 

 

A09084

Fig. 3 -- Horizontal--Right Installation of Pan Extension

HORIZONTAL RIGHT INSTALLATIONS 
Acceptable for Air Conditioner and   
Heat Pump Applications 

HORIZONTAL LEFT INSTALLATIONS 
Acceptable for Air Conditioner   
Only Applications 

 

 

Application A

 

Application F

 

 

 

Application B

 

Application G

 

 

Application C

 

Application H

 

 

 

Application D

 

Application I

 

 

Application E

 

Application J

 

Coil

Ductwork

Airflow

Furnace

Coil

Furnace

Ductwork

Airflow

A13416

Fig. 4 -- Horizontal Installation Applications

Table 1 – Heat Pump Applications

Furnace Width- In. (mm)

Coil Width- In. (mm)

14 (356)

17.5 (445)

21 (533)

24.5 (622)

14 (356)

A

B, C, D, E

D, E

17.5 (445)

A

B, C, D, E

D, E

21 (533)

A

B, C, D, E

24.5 (622)

A

--- Not permitted.

Table 2 – Air Conditioner Applications

Furnace Width- In. (mm)

Coil Width- In. (mm)

14 (356)

17.5 (445)

21 (533)

24.5 (622)

14 (356)

A, F

B, C, D, E, G, H, I, J

D, E, I, J

17.5 (445)

A, F

B, C, D, E, G, H, I, J

D, E, I, J

21 (533)

A, F

B, C, D, E

24.5 (622)

A, F

--- Not permitted.

Содержание CNPHP

Страница 1: ...t serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation NOTE Nitrogen can leak out throu...

Страница 2: ...ory installed hard shutoff TXV designed only for use with R 410A refrigerant Use only with outdoor units designed for R 410A NOTE All TXV S have preset superheat settings and are not field adjustable Cabinet Sweating If this unit is installed in a garage attic or other unconditioned space special attention needs to be given to the potential of cabinet sweating A 6 in 152 mm wide piece of insulatio...

Страница 3: ...plication E Application J Coil Ductwork Airflow Furnace Coil Furnace Ductwork Airflow A13416 Fig 4 Horizontal Installation Applications Table 1 Heat Pump Applications Furnace Width In mm Coil Width In mm 14 356 17 5 445 21 533 24 5 622 14 356 A B C D E D E 17 5 445 A B C D E D E 21 533 A B C D E 24 5 622 A Not permitted Table 2 Air Conditioner Applications Furnace Width In mm Coil Width In mm 14 3...

Страница 4: ... work platform using material in platform that will support the weight of an installer or a service person 2 Place work platform in front of discharge end of furnace 3 Secure platform to building joists Install coil To suspend CNPHP 1 Cut metal plumbers strap to desired lengths 2 Attach metal plumbers strap to four corners of coil casing see Fig 7 3 Use a minimum of two screws per corner to attach...

Страница 5: ...hten Finger tighten plus 1 1 2 turns Be sure to install plastic plug in unused condensate drain fitting Two 3 4 in female threaded pipe connections are provided in each coil condensate pan A trap is not necessary on the condensate line Consult local codes for additional restrictions or precautions If local codes require a trap then the following guidelines are suggested to assure proper drainage I...

Страница 6: ...ARD Failure to follow this warning could result in personal injury or death Provide trap with air gap in drain line when connecting to waste sewer line WARNING Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 01 ...

Отзывы: