INSTALLATION

Shipping Brace

Remove

 2 Screws

Pan Extension

A06031

Fig. 1 -- Model CNPHP Furnace Coil

CNPHP furnace coils are NOT designed to be installed with

furnaces that measure wider than the coil itself.
These units can be installed in multiple configurations. To ensure
proper performance of the system, install and orientate the

components as shown in Fig. 4. Use Tables 1 and 2 to identify
which Application Letters (A through J) are acceptable for the

furnace width and coil width being used in a specific situation.
Orientate and configure the furnace and coil as shown in each

application.
Before installation, there are several other performance
requirements that must be considered because poor installation can

negatively alter performance. The following section will briefly
discuss those factors.

Airflow

Airflow amount and distribution are vital to adequate system

performance. Problems that can be experienced with incorrect
airflow include:

S

low system performance

S

restricted TXV

S

frosted coil

S

poor humidity control

S

water blow--off

NOTE

: In addition, heat pump applications require airflow in a

particular direction for best performance. See decal on front of coil
for correct direction.
When attaching the coil and building the plenum, pay special

attention to the effect these details will have on airflow. After
system start--up, check the cfm to insure that it is correct.

(Generally, the cfm should be 350 to 400 cfm/ton during normal
cooling operation.)

TXV

A thermal expansion valve is utilized in this coil design to optimize

performance and comfort throughout the entire operating range of
the system. Special attention needs to be taken to the TXV when

installing the coil

S

Do not overheat valve. Temperatures that exceed 212

_

F (100

_

C)

can harm valve performance. Use a wet cloth or heat sink when
brazing.

S

Place liquid filter dryer near ID unit to reduce the risk of debris
clogging the valve.

S

Make sure TXV bulb is securely fastened and wrapped in the
indentation on vapor line tube.

CNPHP Models:

These coils have a factory--installed hard--shutoff TXV designed
only for use with R--410A refrigerant. Use only with outdoor units

designed for R--410A.

NOTE

: All TXV’S have preset superheat settings and are not

field--adjustable.

Cabinet Sweating

If this unit is installed in a garage, attic, or other unconditioned

space, special attention needs to be given to the potential of cabinet

sweating. A 6--in (152 mm) wide piece of insulation should be
wrapped around the coil casing and supply duct connection point.

Condensate Management

With proper installation, these coils will manage the condensate
without blow--off into the duct work. The 60 size coil requires the

addition of a pan extension for both horizontal left and horizontal

right position, which is supplied with the coils. See detailed
instructions for more info. Also, refer to Connect Condensate

Drain Line section of this instruction.

PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in property damage.
When installing over a finished ceiling and/or living area,

install a field--fabricated secondary condensate pan under the

entire unit.

CAUTION

!

HORIZONTAL--RIGHT AND HORIZONTAL--

LEFT WITH PAN EXTENSION (5 Ton Size

Only)

1. There are two separate pan extensions shipped with the unit.

For horizontal left installations, use the pan attached to the
left shipping bracket. For horizontal right installations, use
the pan attached to the right shipping bracket. Be sure to use

the correct pan extension for the application. There should
not be any gaps between the plastic condensate pan and the

pan extension. All condensate should flow from the pan
extension to the plastic condensate pan and not leak into the

coil cabinet or duct.

NOTE

: Discard the pan not used along with both shipping

brackets.

2. For horizontal--left installation, install pan extension onto

left end of horizontal--condensate pan. Pan extension is
slotted to fit onto condensate pan edge and will extend into

supply plenum. See Fig. 2.

Supply

Plenum

Condensate Pan

Pan Extension

A06032

Fig. 2 -- Horizontal--Left Installation of Pan Extension

3. For horizontal--right installation, install pan extension onto

right end of horizontal--condensate pan. Pan extension is
slotted to fit onto condensate pan edge and will extend into

supply plenum. See Fig. 3.

Содержание CNPHP

Страница 1: ...t serious hazards which will result in severe personal injury or death WARNING signifies hazards which could result in personal injury or death CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage NOTE is used to highlight suggestions which will result in enhanced installation reliability or operation NOTE Nitrogen can leak out throu...

Страница 2: ...ory installed hard shutoff TXV designed only for use with R 410A refrigerant Use only with outdoor units designed for R 410A NOTE All TXV S have preset superheat settings and are not field adjustable Cabinet Sweating If this unit is installed in a garage attic or other unconditioned space special attention needs to be given to the potential of cabinet sweating A 6 in 152 mm wide piece of insulatio...

Страница 3: ...plication E Application J Coil Ductwork Airflow Furnace Coil Furnace Ductwork Airflow A13416 Fig 4 Horizontal Installation Applications Table 1 Heat Pump Applications Furnace Width In mm Coil Width In mm 14 356 17 5 445 21 533 24 5 622 14 356 A B C D E D E 17 5 445 A B C D E D E 21 533 A B C D E 24 5 622 A Not permitted Table 2 Air Conditioner Applications Furnace Width In mm Coil Width In mm 14 3...

Страница 4: ... work platform using material in platform that will support the weight of an installer or a service person 2 Place work platform in front of discharge end of furnace 3 Secure platform to building joists Install coil To suspend CNPHP 1 Cut metal plumbers strap to desired lengths 2 Attach metal plumbers strap to four corners of coil casing see Fig 7 3 Use a minimum of two screws per corner to attach...

Страница 5: ...hten Finger tighten plus 1 1 2 turns Be sure to install plastic plug in unused condensate drain fitting Two 3 4 in female threaded pipe connections are provided in each coil condensate pan A trap is not necessary on the condensate line Consult local codes for additional restrictions or precautions If local codes require a trap then the following guidelines are suggested to assure proper drainage I...

Страница 6: ...ARD Failure to follow this warning could result in personal injury or death Provide trap with air gap in drain line when connecting to waste sewer line WARNING Manufacturer reserves the right to discontinue or change at any time specifications or designs without notice and without incurring obligations E2014 Bryant Heating Cooling Systems D 7310 W Morris St D Indianapolis IN 46231 Edition Date 01 ...