Local Access
Wall Mounted Equipment Touch
t
Interface
The Equipment Touch interface is a wall mounted
interface used to connect to the RTU Open controller to
access the control information, read sensor values, and
maintenance. This is an accessory interface that does not
come with the RTU Open controller. You wire the
Equipment Touch interface to the RTU Open controller’s
J13 local access port. There are 2 password protected
levels in the display (User and Admin). See the
Equipment Touch Installation and Setup Guide for more
information. See Appendix A for navigation and screen
content.
Field Assistant
Field Assistant is a computer program included with the
purchase of the Tech Tool Kit (USB-TKIT). This is a field
Tech Tool to set-up, service, or download application
software to the RTU Open controller and includes a USB
Link Cable. The link cable connects a USB port to the J12
local access port. See Fig. 58.
RTU Open Controller Troubleshooting —
Communication LEDs:
The LEDs indicate if the
controller is speaking to the devices on the network. The
LEDs should reflect communication traffic based on the
baud rate set. The higher the baud rate the more solid the
LEDs will appear. See Table 19.
NOTE
: Refer to the
RTU Open Multi--Protocol Controller
Controls, Start--Up, Operation and Troubleshooting
manual
for complete configuration of RTU Open controller
operating sequences and troubleshooting information.
Contact your Bryant applications engineer for details on
configuration and troubleshooting of connected networks.
Connect to
computer’s
USB port
Connect to
the Local
Access port
USB Link Kit
RTU Open Controller
Access
Port
J12
P1
P1
P5
P5
LOCAL
ACCESS
PORT
GND
GND
*Therm
mA
*Therm
mA
UI-10
UI-11
SW3
on
COMM
OPTION
CR2032
+
-
SW1
SW2
MSB
LSB
TX
RX
+12 DVC
Rnet-
Rnet+
GND
RNET
J12
J13
J15
J20
C14131
Fig. 58 -- PC Running Field Assistant
Содержание 551J Series
Страница 4: ...4 C160142 Fig 2 Dimensional Drawing Sizes 07 09 ...
Страница 5: ...5 C160143 Fig 2 Unit Dimensional Drawing Sizes 07 09 cont ...
Страница 6: ...6 C13302A Fig 3 Dimensional Drawing Sizes 11 and 12 ...
Страница 7: ...7 C13303A Fig 3 Unit Dimensional Drawing Sizes 11 and 12 cont ...
Страница 39: ...39 a551J 006 Fig 41 RTU Open Controller Wiring Diagram ...
Страница 40: ...40 a551J 007 Fig 42 Typical RTU Open Controller Wiring Diagram Wiring Diagram with Perfect Humidityt System ...
Страница 53: ...53 ...