NLG4 C
24
7.2 Protective circuits and safety features
Description
Condition
Value / range
Insulation test voltage
Mains input to battery output
3750V
Insulation test voltage
Ground/interface to battery:
ground/interface to mains:
2000V
2000V
Leakage current to ground
Un=230V, 50Hz
< 3.5mA
Excess mains voltage
and transient protection
All operating conditions
VDE 0160
IEC 801-2/3/4
Mains fuse
Built in
16A, quick-acting,
double-pole
Excess output voltage
Supply to battery is cut at
maximum charging output
Software-configurable pro-
tection: max. 10% over-
shoot
Physical protection (fixed):
max. 5% overshoot.
Undervoltage at output
Battery almost fully discharged or
not connected
Charging begins only at or
above an adjustable thresh-
old voltage value
Output fuse
Built in
1.5 times the nom. current,
solid-state, single-pole
contactor
Reversed polarity at output
No destructive effect
Protection provided by
built-in or external fuse
Overheating (charger)
All operating conditions
(see 1.5, de-rating)
Linear reduction of output
when risk of semiconduc-
tors and transformers over-
heating
Overheating (battery)
In any phase of the charging cycle Linear reduction of output
or shut-down programma-
ble with hysteresis
Limitation of charging time / charg-
ing energy
In each individual phase of the
charging cycle as well as the total
per charge
Programmable: charger
shuts down after exceeding
limits