12.7.4 Planning the Assembly and Installation of the CPM
CAUTION
Installation of the CPM requires a vehicle with insulation monitor
The CPM may only be installed in vehicles with an insulation monitor. In the CPM the HVDC live parts
are basic insulated against SELV (Safety Extra Low Voltage). As error protection the IT-network of the
vehicle traction circuit is used. If the insulation monitor detects a failure of the insulation, a connection
of the HV-battery should be prevented.
WORK STEP
ILLUSTRATION / OTHER INFO
1
Determine the installation position of the
CPM.
Note the dimensions and installation instructions of the CPM
(user manual ICS) and the dimensions of the vehicle.
2
Determine that work step, for which the
CPM should be available for the installation
in the target vehicle.
Please note, that for the connection of the CPM to the drive
battery, this must already be installed in the vehicle!
3
Ensure the availability of the CPM for the
integration of the CPM in the vehicle for
that work step determined at 2.
Take into consideration the ordering- and delivery times.
4
Ensure the availability of the connections in
the vehicle required for the CPM.
Note the mechanical connection of the CPM in the vehicle as
well as connections to the vehicle battery and to the vehicle
wiring system.
5
Ensure the availability of the auxiliary
equipment and the information (user
manual), in order to be able to undertake
the installation of the CPM, and if
necessary, to be able to check the correct
installation.
Make sure to include corresponding tools in the planning,
CPM-side and also vehicle-side.
6
Ensure, that all information required for the
assembly and installation of the CPM, is
available for the assembly and present
during the assembly.
Note the information- and communication channels.
12.7.5 Transport and Storage of the CPM
CAUTION
Caution during transport and storage of the CPM!
Note the technical specifications of the CPM, e.g. weight. Please note, that with careless handling of
the CPM, injuries are possible: injuries on CPM or packaging, as well as injuries through allowing the
CPM to fall!
Operation Manual
Inductive Charging System
ICS115
60