11
EN
FastFerment™ Setup Instructions
Step 1:
Clean Inside of Conical and Parts.
It’s very important to thoroughly clean your new FastFerment™ before use with the
recommended Five Star Cleaning Supplies and a soft sponge or cloth. The FastFerment™
has not been rinsed or cleaned prior to shipping. Clean and sanitize, soak if possible, all
parts before putting the unit together.
Step 2:
Tape Threads.
Take the supplied Teflon Tape and wrap the following in the direction the threads rotate:
1. Threads at the bottom of the Conical Fermenter
2. Threads on the Collection Ball
3. Thermowell
IMPORTANT NOTE:
If you put the Teflon Tape on backwards the unit could leak.
Step 3: Screw the 6” Screw Top Lid on and off 10 times to break threads in without the
gasket in the Screw Top Lid. (To have the 6” Screw Top Lid easily screw onto the
FastFerment™, the threads need to be broken in).
Step 4: Attach the solid end of the Union Valve to the Conical Fermenter.
Step 5: Attach one of the Union Valve Fittings to the Collection Ball.
Step 6: Attach the Hose to the Hose Barb.
Step 7: Attach the Collection Ball to the Union Valve and open the valve.
Step 8: Insert Grommet into the hole on the top of the 6” Screw Top Lid.
Step 9: Insert the Airlock into the Grommet.
Step 10: Place the completed FastFerment™ into the stand.
Step 11: Do a leak test to ensure that everything seals properly by filing the FastFerment™ with
potable water and leaving it for at least 5-6 hours. If there is a leak, add a few extra
layers of Teflon Tape.
Step 12: Fill FastFerment™ and screw on 6” Screw Top Lid with hollow Gasket.
Step 13: Begin your first batch and have fun!
Step 14: Check out the extra FastFerment™ accessories www.brouwland.com.
THERMOWELL INSTALLATION
Please note that the Thermowell is not screwed into the FastFerment™. You must first wrap the
threads on the Thermowell in the direction that the threads rotate with the supplied Teflon Tape.
Make sure to use Teflon Tape on the threads of the Thermowell when reinstalling it.
If we can do anything to help, please let us know: [email protected] | +32 11 40 14 08
LIMITATION OF LIABILITY
IN NO EVENT WILL Axle Plastic Inc. BE LIABLE, WHETHER IN CONTRACT, TORT, OR OTHERWISE, FOR ANY INCIDENTAL, SPECIAL, INDIRECT,
CONSEQUENTIAL OR PUNITIVE DAMAGES, INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR ANY LOSS OF USE, LOSS OF TIME, INCONVEN-
IENCE, COMMERCIAL LOSS, OR LOST PROFITS, SAVINGS, OR REVENUES TO THE FULL EXTENT SUCH MAY BE DISCLAIMED BY LAW FOR USE
OF FastFerment™ or any accessories or parts associated with FastFerment™.
1
2
3