III- 38
(6) Put the flat cable of the tape sensor PCB ASSY through the portion A of the under cover.
(7) Put the SB PCB harness through the portion B of the under cover.
Fig.3.2-18 Installing the Upper Cover (5)
(8) Pass the link lever through the hole B of the upper cover, and assemble the upper cover
on the ribs of the under cover.
(9) Tighten the upper cover with the two screws A and three screws B.
Note: The screws A are screw, bind B M2.6x4. The screws B are taptite, bind B M2.6x6.
Fig.3.2-19 Installing the Upper Cover (6)
Under cover
“A”
Flat cable of the Tape
sensor PCB ASSY
“B”
Link lever
Upper cover
Screws B
Screws A
Under cover
Upper cover
“B”
SB PCB harness