(6) When NG is displayed in the “Results” column, adjust the VR value. Remove the volume
cover label from the upper cover ASSY.
(7) Turn the VR adjustment volume provided in the machine with using a screwdriver so that
the value indicated in the “Results” column is in the range of 218 to 222.
(Make sure that a screwdriver is put into the slit on the volume and turn it slowly. Do not
turn the screwdriver forcibly since the angle that the screwdriver can be turned is limited.)
Screwdriver
Volume cover label
Slit
Upper cover
Volume
Fig. 38
28