II- 5
2.1.5
Cover Open (Cover Lock) Sensor
The cover open (cover lock) sensor R (push switch) is mounted on the SB PCB ASSY.
The cover open sensor L is secured on the cutter unit ASSY with the screw.
Closing the top cover ASSY, the cover sensor arms R and L push the cover open (cover lock)
sensors (R and L) (push switch) and the signal of top cover ASSY close status is output.
Fig. 2.1-5 Cover Open (Cover Lock) Sensor
Top cover ASSY
Cover sensor arm L
Top cover ASSY
Cover open(cover lock)
Sensor R(push switch)
Cover sensor arm R
SB PCB ASSY
Rib
Cover sensor arm R
Rib
Cover open sensor L
Cover sensor arm L
Rib
Top cover ASSY
Rib
Cover open(cover lock)
sensor L(push switch)
SB PCB ASSY
Cutter unit ASSY
Cover open sensor R