26
(9)
Remove the volume cover label from the upper cover ASSY.
(10) Turn the VR adjustment volume provided in the machine with using a screwdriver so
that the value indicated in the “Results” column is in the range of 218 to 222.
(Make sure that a screwdriver is put into the slit on the volume and turn it slowly. Do
not turn the screwdriver forcibly since the angle that the screwdriver can be turned is
limited.)
Fig. 31
Volume
Screwdriver
Upper cover ASSY
Volume cover label
Slit