3
<General setting>
Fig. 3
Set the General settings screen before examination. Once this screen is set up, it is retained after
the folder is closed.
(1) Setting of items to be examined
Skip the three items below. They are needless for examination.
1. Factory shipment parameter setting
7. Power supply voltage check
9. Sticking and releasing roller holder test
The other items are to be examined.
(2) Setting of port
Click the option “COM1: P-touch9500, COM2: Barcode Reader” in the Port field of the General
settings screen and go to the port setting.
(3) Specification of File for PRN Files (Test Print)
Specify the file for the printing pattern in the PRN Files (Test Print) field in the General settings
screen.
- HG speedy printing
: 9500testHGspeedy.prn (for Europe only)
- HG high resolution printing
: 9500testHGresolution.prn (for Europe only)
- TZ normal printing test
: 9500testTZ.prn
- Avery printing test
: 9500testAV2067.prn (for U.S.A. only)
(4) Setting of the number of times for full cut and half cut
Specify “3 times” for the both full cut test and half cut test fields in the General settings screen.
Содержание PT-9500PC - P-Touch 9500pc B/W Thermal Transfer Printer
Страница 1: ...SERVICE MANUAL MODEL PT 9500PC ...
Страница 2: ...SERVICE MANUAL MODEL PT 9500PC ...
Страница 86: ...IV 10 3 The LED does not turn on 4 No printing is performed ...
Страница 87: ...IV 11 5 The interface malfunction 6 The tape is not cut ...
Страница 88: ...IV 12 7 The tape is not fed correctly ...
Страница 89: ...IV 13 ...
Страница 90: ...IV 14 8 Half cut failure ...
Страница 91: ...IV 15 9 Forced tape eject failure ...
Страница 92: ...IV 16 10 The failure of pressure contact release of the roller holder ...
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ...Sep 2003 8V2054BE0 Printed in Japan ...