III-9
[ 7 ]
Disassembling the Body Cover
(1)
Remove the harness of the tape end sensor ASSY from the groove of the body cover.
(2)
Remove two screws and remove the tape end sensor ASSY.
(3)
Remove the sensor PCB ASSY from the hooks of the body cover in two places bowing the
cover toward outside.
Fig. 3.1-10 Removing the Tape End Sensor ASSY and Sensor PCB ASSY
(4)
Remove two screws from the cassette cover bracket and remove the cassette cover bracket
along the arrow direction.
Fig. 3.1-11 Removing the Cassette Cover Bracket
Sensor PCB ASSY
Body cover
Hooks
Groove
Tape end sensor ASSY
Screws
Cassette cover bracket
Screws
Body cover
Body cover
Cassette cover bracket