II
- 19
[ 8 ] Removing the Roller Holder ASSY, Thermal Head Unit, and Tape Feed Motor from
the Frame ASSY
(1) Remove the retaining ring and pull up the cassette rod.
(2) Remove the retaining ring from the roller holder ASSY.
(3) Unhook the roller holder release spring from the roller holder ASSY and take out the
ASSY and the spring.
NOTE:
When unhooking the spring, take care not to scratch the thermal print head
and its flat cable.
(4) Remove two screws "b" and take off the thermal head unit.
CAUTION:
Do not loosen or remove screws "X."
(5) Remove the retaining ring from the release lever, then take out the release lever,
release rod, and spring.
(6) Push the release rod roller out of the release rod.
(7) Remove two screws "a" and take off the tape feed motor.
Fig. 2.2-15 Removing the Roller Holder ASSY, Thermal Head Unit, and Tape Feed Motor
Содержание PT-2500PC
Страница 1: ...SERVICE MANUAL MODEL PT 2500PC ...
Страница 2: ...SERVICE MANUAL MODEL PT 2500PC ...
Страница 5: ...CHAPTER I SPECIFICATIONS ...
Страница 11: ...CHAPTER II MECHANISMS ...
Страница 49: ...CHAPTER III ELECTRONICS ...
Страница 68: ...CHAPTER IV TROUBLESHOOTING ...
Страница 72: ...IV 3 3 The ON OFF lamp LEDs will not come on 4 No printing is performed ...
Страница 73: ...IV 4 5 Interface malfunctions 6 No tape cutting ...
Страница 74: ...IV 5 7 Tape feeding error ...
Страница 75: ...IV 6 ...
Страница 76: ...APPENDICES Circuit Diagrams A Main PCB B Power Supply PCB ...
Страница 79: ...Nov 98 5V2086BE0 Printed in Japan ...