4 - 36
Adjustment
Hoop sensor adjustment
1. Attach the hoop stay assembly to the feed unit.
2. Enter the test mode, and press [MAIN BOARD TEST MODE] and then [A/D TEST].
3. After the hoop stay assembly's LL-hoop has been attached, press [LL] to save the A/D value.
4. Replace the LL-hoop with the S-hoop, and then press [S] to save the A/D value.
5. After adjustment, move the tubular round arm L, and check that the hoop size matches the display on the test
mode screen.
Содержание PR-600II
Страница 1: ......
Страница 2: ......
Страница 20: ...2 2 Main parts Main unit ...
Страница 33: ...2 15 Disassembly Feed unit Main unit ...
Страница 44: ...2 26 Needle thread unit Main unit ...
Страница 47: ...2 29 Disassembly Needle bar change unit Main unit ...
Страница 50: ...2 32 Thread wiper unit Main unit ...
Страница 54: ...2 36 Needle bar unit Main unit ...
Страница 60: ...2 42 Upper shaft unit Main unit ...
Страница 70: ...2 52 Lower shaft unit Main unit ...
Страница 73: ...2 55 Disassembly Power unit Main unit ...
Страница 78: ...2 60 Thread cut unit Main unit ...
Страница 82: ...2 64 Thread tension unit Main unit ...
Страница 91: ...2 73 Disassembly Operation panel Main unit ...
Страница 98: ...2 80 ...
Страница 100: ...3 2 Operation panel Main unit ...
Страница 108: ...3 10 Thread tension unit Main unit ...
Страница 118: ...3 20 Thread cut unit Main unit ...
Страница 122: ...3 24 Power unit Main unit ...
Страница 128: ...3 30 Lower shaft unit Main unit ...
Страница 132: ...3 34 Upper shaft unit Main unit ...
Страница 147: ...3 49 Assembly Needle bar unit Main unit ...
Страница 157: ...3 59 Assembly Thread wiper unit Main unit ...
Страница 162: ...3 64 Needle bar change unit Main unit ...
Страница 166: ...3 68 Needle thread unit Main unit ...
Страница 170: ...3 72 Feed unit Main unit ...
Страница 188: ...3 90 Main unit Main unit ...
Страница 206: ...4 4 Inspection Blunt needle 1 Touch the needle tip with your finger to check that the needle tip is not blunt ...
Страница 244: ...4 4 Inspection Blunt needle 1 Touch the needle tip with your finger to check that the needle tip is not blunt ...
Страница 282: ...4 42 ...
Страница 311: ...6 1 6Maintenance ...
Страница 333: ......