2-48
Confidential
Error code A5
When scanning the fax, white or black compensation data for the CIS was not within the
correct range.
Error code A6
Although operation was retried due to error A5 that occurred while scanning the fax, white or
black compensation data for the CIS was not within the correct range.
Error code A7
Color parameter in the ROM does not match the CIS.
Error code A8
An error was detected in the color parameter in the ROM during image processing.
Scan Unable
Remove the original document. Turn the power off, then on again.
Scan Unable A6
See Troubleshooting and routine maintenance chapter in User's Guide.
<User Check>
• Turn OFF the power switch, and turn it ON again after a while.
Step
Cause
Remedy
1
Incorrect white level data
Execute
.
2
CIS unit failure
Replace the CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Print Unable A7
Turn the power off and then back on again.
Scan Unable
See Troubleshooting and routine maintenance chapter in User's Guide.
Step
Cause
Remedy
1
Incorrect white level data
Execute
.
2
CIS unit failure
Replace the CIS unit.
3
Main PCB failure
Replace the main PCB ASSY.
Содержание FAX-2950
Страница 20: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 35: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 45: ...2 8 Confidential 2 2 2 Scanning part Fig 2 4 ...
Страница 122: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 130: ...3 6 Confidential 5 LUBRICATION There are no applicable parts for lubrication ...
Страница 136: ...3 12 Confidential 3 New toner sensor PCB ASSY New toner sensor PCB ASSY Main PCB ASSY Guide ...
Страница 140: ...3 16 Confidential 8 Main fan High voltage power supply PCB ASSY Guide Main fan Tape Hole of guide Hole of guide ...
Страница 143: ...3 19 Confidential 12 Speaker unit Guide Speaker harness Guide Guides Guides Speaker unit Main PCB ASSY ...
Страница 153: ...3 29 Confidential 9 3 Cord hook 1 Turn the two cord hooks and then remove them from the machine Fig 3 12 Cord hooks ...
Страница 204: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 217: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 224: ...5 5 Confidential Black and white color scanning Fig 5 1 ...
Страница 263: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 266: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 267: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL REPLACEMENT PARTS 7 1 ...
Страница 268: ...7 1 Confidential 1 PERIODICAL REPLACEMENT PARTS There are no parts to be replaced periodically ...
Страница 269: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 273: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...
Страница 275: ...Confidential APPENDIX 4 HOW TO MAKE PROTECTIVE MATERIAL FOR DRUM UNIT ...