5-63
Confidential
1.3.27 Continuous adjustments of density / registration sensor
(Function code 73)
< Function >
This function is used to perform the following functions consecutively:
Sensitivity adjustment of density sensor (Function code 72), Developing bias voltage
correction (Function code 83), and Adjustment of color registration (Adjustment of inter-color
position alignment) including registration sensor calibration (Function code 66).
< Operating Procedure >
(1) For models with touch panel
Press the [7] and [3] in this order in the initial state of the maintenance mode. “72/83/66-1”
is displayed on the LCD.
For models without touch panel
Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display
“MAINTENANCE 73” on the LCD, and press the [OK]. “72/83/66-1” is displayed on the
LCD.
(2) Press the [SET] or [OK]. “PLS WAIT 72” is displayed on the LCD and each adjustment is
performed in the following order.
1) Sensitivity adjustment of density sensor (Function code 72)
LCD: PLS WAIT 72
2) Developing bias voltage correction (Function code 83)
LCD: PLS WAIT 83
3) Adjustment of color registration (Adjustment of inter-color position alignment)
including registration sensor calibration (Function code 66)
LCD: PLS WAIT 66-1
(3) When all operations are completed, “COMP” is displayed on the LCD. Pressing the [
▼
],
and then the [X] or [Stop]. The machine returns to the initial state of the maintenance
mode.
Note:
If each adjustment fails, “ERROR**” is displayed on the LCD and the adjustment is stopped.
If you press the [
▼
] with “ERROR**” displayed, the details of the error are shown. “**” in
“ERROR **” displayed on the LCD indicates corresponding function code number. Make
sure to take an appropriate remedy after checking the remedy provided in each function
code.
Содержание DCP-L3510CDW
Страница 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Страница 50: ...2 14 Confidential Fig 2 8 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Страница 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Страница 203: ...3 12 Confidential 4 Lower document chute Flat core Second side CIS flat cable Lower document chute ...
Страница 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Страница 212: ...3 21 Confidential 13 High voltage power supply flat cable High voltage power supply flat cable ...
Страница 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Страница 228: ...3 37 Confidential 9 6 Cord hook 1 Remove the Cord hook Two locations Fig 3 15 Cord hooks Cord hook Back side ...
Страница 347: ...5 19 Confidential Fig 5 7 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...