![Brother DCP-L3510CDW Скачать руководство пользователя страница 355](http://html.mh-extra.com/html/brother/dcp-l3510cdw/dcp-l3510cdw_service-manual_53471355.webp)
5-27
Confidential
■
Switching of timing to execute Auto Registration
< Function >
Relative displacement between Cyan, Magenta, Yellow, and Black is detected using the
registration mark sensor, and the Auto Registration is executed at the timing when the
displacement value exceeds the stipulated threshold value.
This function is to switch the threshold value which is used as the timing to execute Auto
Registration. The threshold value can be switched in three phases between High, Mid, and
Low.
“*” is displayed at the end of the currently specified function in the LCD display.
< Operating Procedure >
(1) For models with touch panel
Press the [4], and then the [5] in the initial state of maintenance mode. “USBNo.” is
displayed on the LCD.
For models without touch panel
Press the [
▲
] or [
▼
] in the initial state of maintenance mode to display
“MAINTENANCE 45” on the LCD, and press the [OK]. “USBNo.” is displayed on the
LCD.
(2) Press the [
▲
] or [
▼
] to select “Regi Freq = Low” on the LCD, and press the [SET] or [OK].
(3) “Accepted” is displayed on the LCD, and the machine returns to the initial state of
maintenance mode.
LCD
Description
Regi Freq=Mid
The frequency to execute Auto Registration is middle. (default)
Regi Freq=High
The frequency to execute Auto Registration is high.
Regi Freq=Low
The frequency to execute Auto Registration is low.
Note:
It can be set regardless of the Auto Registration switching function in the function menu.
Even if this function is switched, it does not affect the timing to execute Auto Registration in
the function menu.
Содержание DCP-L3510CDW
Страница 46: ...2 10 Confidential 2 2 2 Scanner part Fig 2 6 Left side Right side Document feed path ...
Страница 50: ...2 14 Confidential Fig 2 8 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 155: ...2 119 Confidential Electrodes location of belt unit Fig 2 16 ...
Страница 193: ...3 2 Confidential 2 PACKING Pad upper R Pad upper L Carton Pad bottom Option carton upper ...
Страница 203: ...3 12 Confidential 4 Lower document chute Flat core Second side CIS flat cable Lower document chute ...
Страница 204: ...3 13 Confidential 5 Panel unit Key flat cable ...
Страница 212: ...3 21 Confidential 13 High voltage power supply flat cable High voltage power supply flat cable ...
Страница 213: ...3 22 Confidential 14 Process drive unit Paper feed motor flat cable ...
Страница 228: ...3 37 Confidential 9 6 Cord hook 1 Remove the Cord hook Two locations Fig 3 15 Cord hooks Cord hook Back side ...
Страница 347: ...5 19 Confidential Fig 5 7 Document scanning position sensor Document detection sensor ADF cover sensor ...
Страница 362: ...5 34 Confidential Print adjustment test pattern Fig 5 8 ...