9. ERROR CODES
9. ERROR CODES
―
71
―
BAS-705
NOTE : Wait 10 seconds or more after turning the power off before turning it back on again.
EMERGENCY STOP switch select-
ed during automatic sewing.
START switch on when power turned
on.
MERGENCY STOP switch on
when power turned on.
The second bar tacking lower shaft
module was open when the power
was turned on.
The cover of the second bar
tacking lower shaft module.
The second bar tacking lower shaft
unit is open or the air pressure is
insufficient.
Abnormal power supply voltage.
Malfunction of loop feed 1 sensor
Malfunction of loop feed 2 sensor
Malfunction of loop feed 3 sensor
Malfunction of loop feed 4 sensor
Malfunction of loop down sensor
Loop feeder retracted
Refer to pages 31.
q
Turn off START switch.
w
Press the RESET switch.
q
Turn off EMERGENCY STOP switch.
w
Press the RESET switch.
q
Turn off the power.
w
Release the air, close the second bar tacking lower
shaft module, and then press the RESET switch.
q
Close the cover of the second bar tacking lower
shaft module.
w
Press the RESET switch.
q
Check the air pressure.
w
Press the RESET switch.
q
Turn off power switch.
w
Check the power supply voltage.
q
Check the operation of loop feed 1 sensor.
w
Press the RESET switch.
q
Check the operation of loop feed 2 sensor.
w
Press the RESET switch.
q
Check the operation of loop feed 3 sensor.
w
Press the RESET switch.
q
Check the operation of loop feed 4 sensor.
w
Press the RESET switch.
q
Check the operation of the loop down sensor.
w
Press the RESET switch.
q
Check that the loop feeder is not retracted.
w
Check if the loop feeder retract position sensor is illuminated.
e
Press the RESET switch.
q
Check the condition of the belt loops.
w
Press the RESET switch.
Error code
Problem
Solution
E-100
E-101
E-102
E-104
E-105
E-106
E-107
E-110
E-111
E-112
E-113
E-118
E-120
E-150
Two joints were detected in succession.