3. PANEL OPERATION
3-2-10. X-Y movement
―
23
―
BAS-705
・
This procedure lets you set the parallel movement of the pattern in the X feed direction
and Y feed direction.
・
The setting range is from -1 to +1 in both the X direction and Y direction. However, it may
not be possible to change the setting within this range because an area check will be
carried out when the setting is changed.
AUTO MODE
◆
Loop length
1st bobbin counter
2nd bobbin counter
ADJUSTMENT(/)
Loop/ program
◆
X-Y/ test feed
X-Y/ feed
1. Press the MODE switch
w
to select AUTO mode.
2. While pressing the SELECT switch
e
, press the
MODE switch
w
.
*
This will change the mode to ADJUSTMENT
mode.
3. Use the
▲
and
▼
SELECT switches
e
to move the
pointer "
◆
" so that "X-Y/program" is selected, and
then press the ENTER switch
t
.
4. Use the
▲
and
▼
SELECT switches
e
again to
move the pointer "
◆
" so that "X move" or "Y move"
is selected.
5. While using the SELECT switch
e
to move the
cursor "
-
" , press the
▲
and
▼
SELECT switches
e
to set the amount of movement.
*
If the CANCEL switch
r
is pressed, the
old previously-set scale ratio will appear again
on the display.
6. Press the ENTER switch
t
.
*
The new scale ratio setting for the X move or Y
move will appear on the display.
▲
X-Y/MOVE/ (ADJ)
Program No.
◆
Xmove (mmx10)
z/
▲
選 択
SELECT
モード
MODE
確 定
ENTER
リセット
RESET
電 源
POWER
取り消し
CANCEL
警 告
WARNING
BAS-705
r
t
e
w
X-Y/MOVE/ (ADJ)
Program No.
◆
Xmove (mmx10)
z/