3. PANEL OPERATION
3-2-3 .Clearing production counter
1. Press the MODE switch
w
to select PROGRAM
mode.
2. Use the
▲
and
▼
SELECT switches
e
to move the
pointer "
◆
" so that "PRODUCTION COUNTER" is
selected.
3. Press the SELECT switch
e
to change the display to "0".
*
If the CANCEL switch
r
is pressed, the old
production counter setting will appear again on
the display.
4. Press the ENTER switch
t
.
*
The production counter setting will now be
cleared.
・
The production counter increases by one each time a single belt loop is sewn.
・
The production counter can count up to a maximum of 9999.
▲
PROGRAM MODE
Production counter
1st bobbin counter
◆
2nd bobbin counter
―
15
―
BAS-705
選 択
SELECT
モード
MODE
確 定
ENTER
リセット
RESET
電 源
POWER
取り消し
CANCEL
警 告
WARNING
BAS-705
r
t
e
w
PROGRAM MODE
◆
Production counter
,,,,
1st bobbin counter
2nd bobbin counter
PROGRAM MODE
◆
Production counter
/
1st bobbin counter
2nd bobbin counter