3-38
Confidential
9.20 Double feeding sensor PCB ASSY (Receive)
(1) Remove the two taptite bind B M3x10 screws to remove the CIS earth plate and the double
feeding sensor upper shield from the lower chute ASSY.
(2) Remove the double feeding sensor PCB ASSY (Receive), and pull out the double feeding
sensor harness (Receive) from the hole on the lower chute ASSY.
(3) Remove the double feeding sensor lower shield from the lower chute ASSY.
Fig. 3-38
Taptite bind B M3x10
Double feeding sensor PCB ASSY (Receive)
Double feeding sensor
harness (Receive)
Double feeding
sensor upper shield
CIS earth plate
Lower chute ASSY
Double feeding
sensor lower shield
Hole