4-6
Confidential
1.5
Acquiring White Level Data
(1) Press and hold the [Stop] and [Scan to USB] buttons simultaneously, and plug the AC
cord into the outlet. The Power LED and the Error LED light.
(2) Press the [Stop], [Scan to USB], [Scan to PC], and [Stop] buttons in this order.
The Scan to PC LED and the Scan to USB LED light.
(3) Press the [Scan to PC] button. The Scan to PC LED and the Scan to USB LED go out,
and the machine enters maintenance mode for service personnel.
(4) Press the [Scan to USB] button six times. The Scan to PC LED and the Power LED light.
(5) Press the [Stop] button. All LEDs go out, and CIS scan area setting starts.
(6) When CIS scan area setting is completed normally, the Scan to PC LED and the Power
LED light. If any error is detected during setting, the Scan to USB LED, the Power LED,
and the Error LED light.
(7) When completed normally, turn off the power of the machine.
1.6
Setting Double Feeding Sensor Threshold
(1) Press and hold the [Stop] and [Scan to USB] buttons simultaneously, and plug the AC
cord into the outlet. Check that the Power LED and the Error LED are lit, and release
these two buttons.
(2) Press the [Stop], [Scan to USB], [Scan to PC], and [Stop] buttons in this order.
The Scan to USB LED and the Scan to PC LED light.
(3) Turn ON the power switch of the computer.
(4) Connect the computer to the machine with the USB cable.
(5) Press and hold the [Stop] button until the Power LED lights.
(6) Double-click "BrADSmt1.exe" that was copied into the temporary folder to start it.
(7) Select the model name in the [Select model:] box, and click the [Start] button.
The double feeding sensor threshold is set.
Note:
• To use remote check mode, the computer needs to be connected to the machine
with the USB cable and the power switch of the computer must be turned ON before
proceeding to step 6.
Содержание ADS-2000e
Страница 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Страница 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 54: ...3 2 Confidential 2 PACKING ...
Страница 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Страница 118: ...7 1 Confidential 1 PERIODICAL MAINTENANCE PARTS There are no parts that must be replaced periodically ...
Страница 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...