3-22
Confidential
(6) Remove the two taptite bind B M3x10 screws, and release the four hooks. Slide the panel
ASSY in the direction of the arrow and release the six tabs from the upper chute.
Fig. 3-18
(7) Open the upper chute from the panel ASSY.
(8) Disconnect the document detection sensor harness, the document scanning position
sensor harness, the double feeding sensor harness (Sent), and the panel PCB harness
from the panel PCB ASSY.
(9) Release the panel PCB harness from the securing fixture, then pull out the panel PCB
harness from the hole on the upper chute.
Fig. 3-19
HARNESS ROUTING: Refer to
.
Note:
• Be careful not to pull any harness.
Assembling Note:
• Make sure that there is no slack in the panel PCB harness when reconnecting it.
Taptite bind B M3x10
Panel ASSY
Hooks
Hooks
Tabs
Upper chute
Tabs
Panel PCB harness
Hole
Upper chute
Panel PCB harness
Double feeding sensor harness (Sent)
Document detection
sensor harness
Panel ASSY
Panel PCB ASSY
Document
scanning position
sensor harness
Содержание ADS-2000e
Страница 15: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Страница 22: ...Confidential CHAPTER 2 TROUBLESHOOTING ...
Страница 28: ...2 4 Confidential 2 2 Paper Feeding Fig 2 2 Feed path ...
Страница 50: ...Confidential CHAPTER 3 DISASSEMBLY REASSEMBLY ...
Страница 54: ...3 2 Confidential 2 PACKING ...
Страница 93: ...Confidential CHAPTER 4 ADJUSTING AND UPDATING SETTINGS AS REQUIRED AFTER PARTS REPLACEMENT ...
Страница 107: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Страница 113: ...Confidential CHAPTER 6 WIRING DIAGRAM ...
Страница 116: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Страница 117: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE CONTENTS 1 PERIODICAL MAINTENANCE PARTS 7 1 ...
Страница 118: ...7 1 Confidential 1 PERIODICAL MAINTENANCE PARTS There are no parts that must be replaced periodically ...
Страница 119: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Страница 123: ...Confidential APPENDIX 3 INSTALLING MAINTENANCE DRIVER ...