Section 5 - Detailed Configuration
Brooks DeviceNet PCs
5.5.2.5. Note: Initial Comm. Characteristics
Table 5-38 Bit Descriptions
Bit
7 6 5 4 3 2 1 0
Description
Initial Production Characteristics
Initial Consume Characteristics
Table 5-39 Initial Production Characteristics
Value Description
0
Produce Across Message Group 1
1
Produce Across Message Group 2 (Destination)
2
Produce Across Message Group 2 (Source)
3
Produce Across Message Group 3
Table 5-40 Initial Consume Characteristics
Value Description
0
Consume Across Message Group 1
1
Consume Across Message Group 2 (Destination)
2
Consume Across Message Group 2 (Source)
3
Consume Across Message Group 3
5.5.2.6. Note: Watchdog Timeout Action
Table 5-41 Watchdog Timeout Action
Value Timeout
Action
Description
0
Transition to Timed Out
The Connection transitions to the Timed Out state and remains in that state until
Deleted or Reset. Invalid value for Explicit Connections
1
Auto Delete
The Connection Class automatically deletes the Connection if an
Inactivity/Watchdog timeout occurs
2
Auto Reset
The Connection remains in the Established State and restarts the
Inactivity/Watchdog timer