Section 5 - Detailed Configuration
Brooks DeviceNet PCs
5.4.3. Service Details
NONE
5.5. Connection Object [0x5]
5.5.1. Rules Governing Master/Slave Connections [0x5]
The Connection Object configures the characteristics and behavior of a
logical connection in the device. A Connection is allocated (opened) in the
device by the Master via the Allocate M/S Connection Request service in the
DeviceNet Object. Configuration of the Connection Object attributes for the
requested connection is done automatically in the device and generally need
no further modification except for setting the Expected Packet Rate attribute
(Attribute 9). However, it is within this object that selection of Input/Output
assemblies may be configured. There are two ways to perform this
configuration:
Modification of Attribute 100 and 101 in the M/S Explicit Connection
OR
Modification of the Produce and Consume Path attributes (Attribute 14 and
15 respectively) in the I/O Connection Objects
OR
Via diagnostic port using Brooks Service Suite.