![Brooks SLA5800 Series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/brooks/sla5800-series/sla5800-series_supplemental-manual_2818721060.webp)
Installation and Operation Manual
X-DPT-DeviceNet-SLA5800-SLAMf-Series-RevB-PC-eng
Part Number: 541B200AAG
March, 2015
46
Section 5 - Detailed Configuration
Brooks DeviceNet PCs
5.5.2. Attributes
Table 5-30 Connection Object Instance 0 Attributes
Attrib
ID Name
Data
Type
Access
Rule NV
Description
Notes
1
Revision
UINT
Get
NV
Revision of the Connection
object class definition upon
which the implementation is
based.
If updates require an increase
in this value, then the value of
this attribute increases by 1.
Range 1– 65535
5.5.2.1. Explicit Connection Attributes
Table 5-31 Instance 1 - M/S Explicit Connection Attributes
Attrib
ID Name
Data
Type
Access
Rule Description
Notes
1
State
USINT
Get
State of Object
Note: ‘State’ below
Default: 3 = Established State
2
Instance Type
USINT
Get
Indicates type of Connection
Default: 0 = Explicit Connection
3
Transport Class &
Trigger
USINT Set
1
Defines behavior of Connection
Placed in CAN Identifier
Note: ‘Transport Class &
Trigger’ below
Default: 0x83
4 Produced
Connection ID
UINT
Get
Placed in CAN Identifier Field when
the Connection transmits
5 Consume
Connection ID
UINT
Get
CAN Identifier Field value that
denotes message to be received
6 Initial
Comm
Characteristics
BYTE
Get
Defines the Message Group(s)
across which productions and
consumptions associated with this
Connection occur
Note: ‘Initial Comm
Characteristics’ below
Default: 0x21
7 Produced
Connection Size
UINT Set
1
Maximum number of bytes
transmitted across this Connection
Default: 0x017C
8 Consumed
Connection Size
UINT
Get
Maximum number of bytes received
across this Connection
Default: 0x017C
1
Settable while the connection is in the Configuring State.