Optional Equipment
Transmitter
The transmitter provides accurate magnet angle detection and conversion
to a 4 - 20 mA industry standard output signal, based on the position of a
float assembly in the flowmeter. This rugged, compact, microprocessor-
driven device is capable of providing accurate flow information to your
external support systems. The patented magnetic sensor with automatic gain
control enables an extremely high dynamic capture range without sacrificing
accuracy.
Reference Transmitter Wiring Diagram Figure 1-3
Figure 1-1 Model MT3750C with
Transmitter
Table 1-7 Approvals - MT3750C with Transmitter
Mechanical
Tr
an
smi
tte
r
Indu
cti
ve
Switch
Alar
m
Reed Switch Alar
m
ATEX
IECEX
UL
NEPSI
Explosion safety
"Intrinsic Safety (ia)"
ATEX
IECEX
NEPSI
Explosion safety
"Non-sparking (nA)"
IECEX
Russia Custom Union
Excessive Pressure
Russia Custom Union
Explosion safety
II 2 G Ex ia IIC T6
II 2 D Ex iaD 21 IP66/IP67 T70°C, II 2 D Ex tD A21 IP66/IP67 T70°C
EN 60079-0:2006, EN 60079-11:2007
EN 61241-0:2006, EN 61241-11:2006
Ex d IIC T6 Gb
GB3836.1-2010 GB3836.2-2010
Ex ia IIC T6
IEC 60079-0:2004 IEC 60079-11:1999
Class I, II, III, Div.1, Groups A, thru G, T6
Class I, Zone 1 AEx ia IIC T6, Ex ia IIC T6
Ex ia IIC T6 Gb
Ex iaD 21 T70°C
GB3836.1/4-2010, GB 12476.4-2010
Ex nA II T6
Class I, Div.2, Grps A, B, C, and D;
Class II Grps F and G, T6
Class I, Zone 2 AEx nA II T6, Ex nA II T6
Custom Union including Russia
"On safety of the equipment for work in explosive environments"
ТR СU 012/2011 (TR CU Ex)
Custom Union including Russia
“On safety of the equipment operating under excessive pressure”
TR CU 032/2013
Meter Options
EX d IIC T6
IEC 60079-0:2004 IEC 60079-1:2003
Special conditions for safe use:
For information regarding the dimension of the flameproof joints the
manufacturer shall be contacted.
Class I, Div.1, Groups A, B, C, and D,T6
Class II, Div.1, Groups E, F, and G
Class I, Zone 1 AEx d IIC T6, Ex d IIC T6
II 2 G Ex d IIC T6
II 2 D Ex tD A 21 IP66 T 85°C
EN 60079-0:2006, EN 60079-1:2004, EN 61241-0:2006, EN 61241:2004
Special conditions for safe use:
For information regarding the dimension of the flameproof joints the
manufacturer shall be contacted.
Explosion safety
"Flame Proof"
Table x-xx Product Approvals - 3750 With Transmitter
Standards/Directives/Marking
Approvals
Mark
KEMA 01ATEX2174
IECEx KEM 06.0049
UL File E73889
GYJ11.1638X
KEMA 01ATEX1033
IECEx KEM 06.0037
1292059
GYJ11.1637
IECEx KEM 06.0037
1292059
TC N RU Д-U.AУ04.B.05988
RU C-HU.ГБ08.B.00741
Declaration/Certificate
Содержание Ar-Mite MT3750
Страница 15: ...Section 1 Introduction 11 Figure 1 10 Dimensions for MT3750C Panel Mounting Brooks Ar MiteTM MT3750C...
Страница 19: ...Section 2 Installation 15 Figure 2 3 Inductive Switch Wiring Brooks Ar MiteTM MT3750C...
Страница 24: ...Section 2 Installation 20 Figure 2 7 Transmitter Wiring Diagram for I S Systems Brooks Ar MiteTM MT3750C...
Страница 25: ...Section 2 Installation 21 Figure 2 8 Transmitter Wiring Diagram for XP Systems Brooks Ar MiteTM MT3750C...
Страница 26: ...Section 2 Installation Brooks Ar MiteTM MT3750C 22 Figure 2 9 Transmitter Wiring Diagram...
Страница 30: ...Section 3 Operation Brooks Ar MiteTM MT3750C 26 Figure 3 1 Reed Switch Alarm...
Страница 34: ...Section 5 Parts List 30 Figure 5 1 Model MT3750 Exploded View Brooks Ar MiteTM MT3750C...