When the installation is not possible with glass of expansion oponed for
technical motives, it will be a responsibility only of the installer to carry out the
installation of the boiler with glass of expansion closed, That´s why it´s
necessary to pay attention on a series of minimal requirements of safety.
1) It is necessary to foresee in the installation of the radiators not to place
closings with thermostatic valves of zone in all the radiators. Always there has to
stay a minimal part of the installation (radiators) opened in order that the
heating home could remove the overheating.
2) It is obligatory to place a safety valve adjusted to 3 bar of pressure. The
installation must fill to 1 Bar of pressure.
3) It is recommended to place a valve of thermal unload (95ºC). The outlet of
this valve must be wide, placed in visible and protected place to avoid spilling
outside or splashes. It is obligatory to avoid all kinds of siphon in the pipelines
that go to the glass of expansion.
4) The pressure of load of the glass must be the same that that of filling of the
installation. The volume of the glass of expansion must be proportional to the
water volume of the installation.
5) It is advisable to place in the installation a thermostat of minim, which cuts the
circulator providing that the water of the large water deposit of the this home
below it 50ºC. This will avoid the condensations that take place when the home
is turns on.
6) It is advisable that all the components of the installation (safety valve,
circulator, glass of expansion etc.) are placed in the return
5
5
5
5
KITS DE INSTAL
KITS DE INSTAL
KITS DE INSTAL
KITS DE INSTALA
A
A
ACIÓN OPCIONALES
CIÓN OPCIONALES
CIÓN OPCIONALES
CIÓN OPCIONALES /
/
/
/
OPTIONAL KITS OF
OPTIONAL KITS OF
OPTIONAL KITS OF
OPTIONAL KITS OF
INSTALLATION
INSTALLATION
INSTALLATION
INSTALLATION
Para complementar esta gama y garantizar un perfecto funcionamiento de la
misma, se ofrecen unos kits pre-montados, que se conectan a la caldera
simplemente uniendo los tubos del sistema hidráulico.
To complement this range and to guarantee a perfect functioning of the same
one, a few pre-mounted kits, which are offered connected to the boiler simply
joining the pipes of the hydraulic system.
•
KIT
KIT
KIT
KIT----1.
1.
1.
1. Modulo para la gestión de instalaciones de calefacción alimentadas
por una caldera a leña para la producción de agua caliente destinada a
instalaciones de calefaccion doméstica y ACS.
•
KIT-1. Module for the management of facilities of heating fed by a boiler to
fuelwood for the production of warm water destined for facilities of
domestic heating and hot sanitary water (HSW).
La producción de ACS es prioritaria y viene automáticamente relevada del
sistema hidraulico por mediación de un detector de flujo.
Funcionamiento:
Funcionamiento:
Funcionamiento:
Funcionamiento:
La desviadora hace recircular el agua primaria en el intercambiador de placas
cuando el flujostato detecta una solicitud de agua caliente sanitaria.