Bronkhorst®
Vapor Delivery Module
9
9.17.079
3.4.3
Capacities
Figure 1: Capacity SW-100 Vaporizer Figure 2: Capacity SW-200 Vaporizer
3.4.4
Pressure rating
• Gas supply = max. 10 bar(g)
• Liquid supply = max. 10 bar(g)
• Vapor pressure = atmospheric
3.5
Piping
For optimal performance of the system it is recommend to have at least 10 pipe diameters distance between the angle and the
equipment inlets. The purge is rarely used in production environments, except for installation.
Be sure that piping is absolutely clean!
CAUTION - DO NOT install small diameter piping on high flow rates.
CAUTION - DO NOT mount abrupt angles directly to the inlet or outlet, especially for high flow rates.
3.6
Electrical connections
3.6.1
Mains
Model
Power supply
[Vac]
Maximum power
(included tracing §3.6.2)
Fuse primary
heater
Fuse secondary
heater
Fuse main
SW-10n-n-50-a-nn-a
110 … 120
250 [VA] | 50-60 [Hz]
T2[A]
T4[A]
T2[A]
SW-10n-n-51-a-nn-a
110 … 120
550 [VA] | 50-60 [Hz]
T2[A]
T4[A]
T2[A]
SW-20n-n-50-a-nn-a
110 … 120
250 [VA] | 50-60 [Hz]
T2[A]
T4[A]
T2[A]
SW-20n-n-51-a-nn-a
110 … 120
550 [VA] | 50-60 [Hz]
T2[A]
T4[A]
T2[A]
SW-10n-n-30-a-nn-a
220 … 240
250 [VA] | 50-60 [Hz]
T1[A]
T4[A]
T1[A]
SW-10n-n-31-a-nn-a
220 … 240
550 [VA] | 50-60 [Hz]
T1[A]
T4[A]
T1[A]
SW-20n-n-30-a-nn-a
220 … 240
250 [VA] | 50-60 [Hz]
T1[A]
T4[A]
T1[A]
SW-20n-n-31-a-nn-a
220 … 240
550 [VA] | 50-60 [Hz]
T1[A]
T4[A]
T1[A]
For mains connection, use appropriate cabling with IEC 60320-1/C19 connector:
• Power cable with Euro Plug (EU) – Schurter #6051.2043 (art.nr.1.15.242)
• Power cable with Switzerland Plug (CH) (art.nr.1.15.243)
• Power cable with North America Plug (USA) – Schurter #6051.2041 (art.nr.1.15.244)
• Power cable with United Kingdom Plug (UK) – Schurter #6051.2048 (art.nr.1.15.245)