background image

25

 15.  MOBILED

 

   The MobiLED lamp was developed to suit the Move 1200 L RFS 2 

power pack: exceptionally compact and light, MobiLED has a 
tilt-and-swivel head for single-handed operation and an in-
tegral reflector mounting. The intelligent ventilation control 
only switches on when the operating temperature demands 
it. The unique design requires very little space for transport 
and storage.

 

   The  continuous  operation  mode  of  the  Move  1200  L  RFS  2 

enables  the  use  of  powerful  LEDs  for  modelling  light  so 
as to create new light design effects. Especially at the day-
light colour temperature of 5500 K, it offers completely new  
possibilities for film sequences.

 

   Important note: all MobiLED lamps with the serial numbers N08, N10, N12 and O04 must be 

modified in our Service Centre before use with the Move 1200 L RFS 2 power pack.

 15.1  Replacing flash tubes
 

   Before you change the flash tube, be sure to disconnect the lamp from the power pack! Plug-in 

flash tubes are used. 

 

   To change a flash tube, remove the snap ring and take out the protecting glass. Then pull the flash 

tube axially out of its socket. When replacing the flash tube make sure it is pushed in as far as it 
will go. Finally replace the protecting glass and secure it with the snap ring. Protecting glasses are 
available in the versions "UVE" art. no. 34.339.00 (5500 K) and "UVE matt" art. no. 34.340.00 (5500 K).

 15.2  Lamp plugs
 

   Lamp plugs and connections are fitted with mechanical interlocks to prevent unintentional dis-

connection. To unplug, push down the locking spring below the cable guide and pull the plug out 
of its socket.

 15.3  Extension cable to MobiLED
 

   The extension cable (3.5 m / 11.5 ft), available as an accessory under art. no. 34.150.00, is espe-

cially thin and flexible. It is only intended for use with MobiLED, Mobilite and Mobilite 2. If the cable 
is used with other lights, the modelling light and cooling fan will not operate.

 15.4  Lamp fuses
 

   Use only sand-filled fuses of the type indicated on the type plate!

 

 

Max. energy

Move 1200 L RFS 2 Comments

Mobilite 
Mobilite 2

1600 J


x

Modification required (Service) 
Modification required (Service)

MobiLED

1600 J

x

Modification required (Service) 
for serial numbers: 
N08, N10, N12, O04

Litos

2400 J

-

Picolite

1600 J

x*

Flash yes, modelling light no

Primo 1600 J 
Pulso F2 / Hazy 2

1600 J

x*

Flash yes, modelling light no

Pulso G 1600 J 
Unilite 1600 J

1600 J

x*

Flash yes, modelling light no

Pulso G 3200 J 
Unilite 3200 J

3200 J

x*

Flash yes, modelling light no

Pulso F4 / Hazy 4 

3200 J

x*

Flash yes, modelling light no

Pulso Twin 2 x 3200 J

x*

Flash yes, modelling light no

Primo 3200 J

x*

Flash yes, modelling light no

Lightbar  
Striplite

3200 J 
3200 J

x*

Flash yes, modelling light no

Pulso Spot 4

3200 J

x*

Flash yes, modelling light no

Ringflash C 
Ringflash P

3200 J 
3200 J

x*

Flash yes, modelling light no

Litestick

3200 J

x*

Boxlite 40 (A3)

3200 J

x*

Flash yes, modelling light no 
No. of flashes per sequence is  
limited (see marking on lamps!)

Pulso 8 / Hazy 8

6400 J

-

Содержание Move 1200 L RFS 2

Страница 1: ...Move Operating instructions...

Страница 2: ...Luis Alvarez USA...

Страница 3: ...1 q p 7 Power selector lamp 2 q p 8 Master power selector q p 9 Modelling light on off 10 eco key more flashes per battery 11 RFS 2 interface on off Photocell on off key 12 LCD display 13 Battery leve...

Страница 4: ......

Страница 5: ...ng instructions in a safe place and pass them on to further users if necessary Observe the safety instructions Contents Page Important safety instructions 8 1 Scope of delivery 11 2 Startup 12 3 Opera...

Страница 6: ...echanical interlocks When plugging in ensure that the interlocks engage completely To unplug push down the locking spring below the cable guide and pull the plug out of its socket Prior to replacing f...

Страница 7: ...tecting glass or a UV coated lamp must be used Before startup the lamp must be mounted on a stand or suspended from a suitable mounting When a lamp is suspended it must be secured to the mounting with...

Страница 8: ...t is compulsory that they are modified in our Service Centre before use with the Move 1200 L RFS 2 power pack Do not expose rechargeable batteries to excessive heat e g sunshine fire or likely Shippin...

Страница 9: ...1200 L RFS 2 31 016 XX 2 MobiLED 32 013 00 Softbox 60 x 60 2 ft x 2 ft 33 561 00 Umbrella 85 cm 33 5 33 574 00 Outdoor Trolley backpack 36 519 00 Move 1200 L RFS 2 31 016 XX 1 MobiLED 32 013 00 Outdoo...

Страница 10: ...12 2 STARTUP 1 Charge battery 2 Press the on check key 3 Click the battery into place 4 Switch on the power pack...

Страница 11: ...he modelling light switches off automatically to save power example mod10s modelling light is on for 10 seconds Eco operation 10 When eco is activated the charging time is twice as long At the same ti...

Страница 12: ...as follows The battery charge display blinks to indicate a low state of charge Once the warning message Battery low appears the power pack is no longer available for use and must be recharged All sett...

Страница 13: ...e ca 5 During charging 1 2 3 Battery empty and is being recharged Battery is 50 charged Battery is 80 charged Battery is fully charged Fault messages at battery 1 2 3 Battery temperature too high Allo...

Страница 14: ...t be discharged too far The unit switches off automatically when the battery voltage is too low However because there is a small leakage current even when the unit is switched off we strongly recommen...

Страница 15: ...ed on to conserve the battery cont mode for continuous operation sequence off 2 50 Selection of a certain number of flash releases from 2 50 As soon as activated the info display shows the number in t...

Страница 16: ...ation 1 Press the menu key 15 to enter the main menu 2 Use the selection key 14 to scroll down to the menu item modelling light 3 Press the menu key 15 again to select the function The display begins...

Страница 17: ...speed mode the colour temperature is slightly colder but remains constant over the energy setting range 8 2 Controlling flash times with the flash duration setting in the main menu In the main menu y...

Страница 18: ...ou need for this is the RFS 2 2 transmitter which is available for Canon Fuji Nikon and Sony cameras Please read the operating instructions for the RFS 2 2 transmitter to learn more about optimum use...

Страница 19: ...ceiver is not included in the power pack s scope of supply 10 2 Photocell cell 2 The photocell can be switched on and off using the sync key 11 When it is active the blue LED beside the cell label 2 i...

Страница 20: ...power pack was shipped energy unit J Ws Choice of unit for energy on the info display serial number Displays the serial number Only for Service country Displays the country code Only for Service Power...

Страница 21: ...g circuit overheated cooling phase 15 min Thermo 2 Capacitors overheated cooling phase 60 min Thermo 3 Resistors overheated cooling phase 3 min Thermo 4 Battery overheated cooling phase 15 min Thermo...

Страница 22: ...te 1600 J 1600 J x Flash yes modelling light no Pulso G 3200 J Unilite 3200 J 3200 J x Flash yes modelling light no Pulso F4 Hazy 4 3200 J x Flash yes modelling light no Pulso Twin 2x3200 J x Flash ye...

Страница 23: ...sure to disconnect the lamp from the power pack Plug in flash tubes are used To change a flash tube remove the snap ring and take out the protecting glass Then pull the flash tube axially out of its...

Страница 24: ...adapter and the adapter cable it is possible to use the modelling light independently of the power pack and the mains power supply With this arrange ment the MobiLED s modelling light can be supplied...

Страница 25: ...Halogen max 2x100 W or 2xLED 30 W Setting for modelling light duration 10 30 60 s Continuous operation for 2 hours Colour temperature ECTC Enhanced Colour Temperature Control technology for constant c...

Страница 26: ...e for the first owner on the above bron color products Exceptions to this rule are flash tubes halogen lamps protecting glasses cables batteries rechargeable batteries and textiles Faults resulting fr...

Страница 27: ...Tim L din Switzerland...

Страница 28: ...Bron Elektronik AG CH 4123 Allschwil Switzerland www broncolor swiss Urs Recher Switzerland BA107 00 04 18...

Отзывы: