23
Acoustic fault indicator
If the flash fails to fire, a warning signal sounds for ca. 0.5 s and the display (4) for the appropriate
lamp blinks.
Acoustic signals
Beep sound:
End of charging or discharging
Double beep:
Energy demand above or below energy control setting via RFS 2 transmitter
"test" key held pressed for 4 s (reset to works settings)
Message in display
Description
Thermo 1
Charging circuit overheated
(cooling phase = 15 min)
Thermo 2
Capacitors overheated
(cooling phase = 60 min)
Thermo 3
Resistors overheated
(cooling phase = 3 min)
Thermo 4
Battery overheated
(cooling phase = 15 min)
Thermo 5
Battery overheated
(cooling phase = 20 min)
Accu low 20 %
Appears on reaching 20 % energy
remaining in battery
Charge defect
Unit must be sent to Service
for repair
Overvoltage
Unit must be sent to Service
for repair
Defect lamp 1 / lamp 2
Lamp 1 or lamp 2 is defective
or not correctly connected
Use broncolor tubes
Please use only original broncolor
flash tubes
13. INFORMATION AND FAULT SIGNALS
Display
Options
Description
daily counter
Number of flashes since the last reset
(reset with the "menu / enter" key)
flash counter
Number of flashes since the power pack
was shipped
energy unit
J
Ws
Choice of unit for energy on the info display
serial number
Displays the serial number. Only for Service
country
Displays the country code. Only for Service
Power timeout
16 – 120 min
Automatically switches the power pack
off after so many minutes without use.
prog.version
Displays the program version. Only for Service