4.  

Flash tube 

 

The flash tube is pluggable. To replace it, fire a flash, disconnect unit from 
power, and allow to discharge and cool off for ten minutes. Then press the 
spring radially inward and carefully remove or plug in the flash tube. The 
spring acts as the electrical contact and also prevents the tube from falling 
out. 
 
For Minipuls C200 following 1500 J flash tubes are available. 

 

coating for 5500 K 

   

art. no.  

34.310.55 

 
 

5.  

 

Protecting glass 

 

For safety reasons, never operate a unit without the protecting glass in 
place. 
 

 

- Clear protecting glass for Minipuls C200 art. no. 34.336.59 

 
 

6.  

 

Modelling light 
 

The unit is equipped with a very bright halogen modelling light. The 
maximum tolerated modelling light output supplies: 
 
Minipuls C200  

650 W  220 - 240 V, 300 W  110 - 120 V 

 
 
In order to meet the European security standard, the modelling lamps 
which are offered by the manufacturer must be used.  
 
 

7.  

Fuse 

 

The fuse (5) is located on the rear of the unit. Sand-filled fuses with a 
value 3.15 AF may only be used (sand-filled fuses can be identified by 
their opaque fuse container). Using an incorrect fuse is dangerous: it may 
cause the halogen lamp to burst. The correct fuse is therefore included 
with each original broncolor replacement lamp.

 

 
 

8.  

Heating/temperature monitor 

 

In the proximity of the halogen lamp, the unit, depending on adapters 
used, can acquire high temperatures. For this reason, we recommend 
touching

 

the unit on the

 

handle behind

 

or on the stand adapter

 

only. Due 

to the intense heat radiation when a modelling light is in operation, keep 
the unit at a minimum distance of 1 m from flammable surfaces.  

Содержание Minipuls C200

Страница 1: ...Operating instructions minipuls C200 www broncolor com...

Страница 2: ...hem on to further users if necessary Observe the safety instructions Contents page Safety information 3 Controls and displays 4 Front panel for Minipuls C200 5 1 Minipuls C200 6 2 Application 6 3 Comm...

Страница 3: ...2...

Страница 4: ...itable for use in an explosions hazard environment The accessories mounted to the unit may heat up to high temperatures under specific conditions Handle with care To protect against the effects of rad...

Страница 5: ...4 Connection socket for mains cable 5 Fuse 6 Switch for modelling light proportional full 7 Switch for modelling light on off 8 Main switch on off 9 Slave cell on off 10 Infrared receiver on off 11 Ro...

Страница 6: ...5 Front panel for Minipuls C200...

Страница 7: ...to the mounting and rotate in any direction 3 2 Please check that the mains supply corresponds to the information on the label of the unit Connect unit to earthed power 3 3 Switch on main switch 8 and...

Страница 8: ...t output supplies Minipuls C200 650 W 220 240 V 300 W 110 120 V In order to meet the European security standard the modelling lamps which are offered by the manufacturer must be used 7 Fuse The fuse 5...

Страница 9: ...adapter will accept standard broncolor bolts and Manfrotto pins Make sure the lamp is firmly attached to the stand before operating The click stops of the locking handle can be adjusted by pulling it...

Страница 10: ...allows you to use the full line of broncolor reflectors For a complete summary please consult the broncolor system catalogue Be Creative with Light And with System 14 Service and repair Your broncolor...

Страница 11: ...kg From year of production 1995 serial number begins with C compatible with Minipuls C200 Subject to change in the interest of technical development 16 Order numbers for diverse spare parts accessorie...

Отзывы: