7
4.
Flash tube
The flash tube is pluggable. To replace it, fire a flash, disconnect unit from
power, and allow to discharge and cool off for ten minutes. Then press the
spring radially inward and carefully remove or plug in the flash tube. The
spring acts as the electrical contact and also prevents the tube from falling
out.
For Minipuls C200 following 1500 J flash tubes are available.
coating for 5500 K
art. no.
34.310.55
5.
Protecting glass
For safety reasons, never operate a unit without the protecting glass in
place.
- Clear protecting glass for Minipuls C200 art. no. 34.336.59
6.
Modelling light
The unit is equipped with a very bright halogen modelling light. The
maximum tolerated modelling light output supplies:
Minipuls C200
650 W 220 - 240 V, 300 W 110 - 120 V
In order to meet the European security standard, the modelling lamps
which are offered by the manufacturer must be used.
7.
Fuse
The fuse (5) is located on the rear of the unit. Sand-filled fuses with a
value 3.15 AF may only be used (sand-filled fuses can be identified by
their opaque fuse container). Using an incorrect fuse is dangerous: it may
cause the halogen lamp to burst. The correct fuse is therefore included
with each original broncolor replacement lamp.
8.
Heating/temperature monitor
In the proximity of the halogen lamp, the unit, depending on adapters
used, can acquire high temperatures. For this reason, we recommend
touching
the unit on the
handle behind
or on the stand adapter
only. Due
to the intense heat radiation when a modelling light is in operation, keep
the unit at a minimum distance of 1 m from flammable surfaces.