background image

LP GAS CYLINDER – 20Lb 

 

QCC®-1 QUICK CLOSING COUPLING 

1.  All OMC models are designed to be used with an LP gas 

cylinder equipped with the QCC®-1 Quick Closing 
Coupling system. 

 

2.  The QCC®-1 system incorporates safety features required 

by the American National Standards Institute (ANSI) and 
the Canadian Standards Steering Committee.

 

•  Gas will not flow until a positive connection has been 

made.

 

•   A thermal element will shut off the flow of gas between 240° 

and 300° F.

 

•   When activated, a Flow Limiting Device will limit the flow of 

gas to 10 cubic feet / hour. 

 

 

 

 

 

 

3. 

The LP Gas Cylinder is not included with the Gas 
Stove. 

Be sure to purchase one with the QCC® valve. 

This valve is recognized by the external threads on the 
inlet port of the valve. QCC® equipped cylinders are 
available from your Gas Stove Dealer.

 

NOTE: Any attempt to connect the regulator, by use of 
adapters or any other means, to any other valve could 
result in damage, fire or injury and may negate the 
important safety features in the QCC®-1 system. 

 

SPECIFICATION 

1.  All  LP  gas  cylinders  used  with  this  appliance  must 

be constructed and marked in accordance with the 
Specifications for LP Gas Cylinders of the U.S. 
Department of Transportation (D.O.T.) or the National 
Standard of Canada, CAN/CSA-B339, Cylinders, 
Spheres and Tubes for Transportation of Dangerous 
Goods ; and Commission, as applicable 

2.  The LP gas cylinder used for this appliance must not 

have a capacity exceeding 20 lb. (9 kg).

 

•    Approximately 18” (46cm) high and 12” (31cm)

 

Diameter. 

3.  All LP gas cylinders used with this appliance should be 

inspected at every filling and re qualified by a licensed 
service outlet at the expiry date (10 years), in accordance 
with the DOT (USA) and Canadian Transport 
Commission (Canada) codes for LP Gas Cylinders. 

4. 

All LP gas cylinders used with this appliance must be 
provided with a shutoff valve terminating in a cylinder 
valve outlet No. 510, specified in the Standard for 
Compressed Gas Cylinder Valve Outlet and Inlet 
Connection (USA) ANSI/CGA-V-1-1977 (Canada) CSA 
B96.

 

5.  The cylinder supply system must be arranged for vapor 

withdrawal. 

 

6.  The cylinder must include a collar to protect the cylinder 

valve. 

7.  The cylinder must be installed as per assembly 

instructions. 

8.  Never fill the cylinder beyond 80% full. A fire causing 

death or serious injury may occur. 

9.  The cylinder valve must include a safety relief device 

having direct communication with the vapor space of the 
cylinder. 

 

HANDLING 

1.  Government  regulations  prohibit  shipping  full  LP  gas 

cylinders. You must take your new cylinder to a LP gas 
dealer for filling 

2.  A filled LP gas cylinder is under very high pressure. 

Always handle  carefully  and  transport  in  the  upright  
position. Protect the valve from accidental damage. 

3.  Do not tip the LP gas cylinder while connecting it to the 

regulator. Fasten the cylinder securely during transport, 
use and storage. 

4.  If the cylinder is tipped after it is connected to the 

regulator, shut off the gas, disconnect the regulator and 
have it checked before using it again. 

 

STORAGE 

1.  Store the LP gas cylinder outdoors in a well-ventilated 

place. 

2.  Do not store the LP gas cylinder in direct sunlight, near a 

source of heat or combustion. 

3.  If you intend to store the stove indoors, disconnect and 

remove the LP gas cylinder first. Disconnected cylinders 
must have a dust cap installed and must not be stored in 
a building, garage or any enclosed area. 

4.  Keep out of the reach of children. 
5.  When the LP gas cylinder is connected to the gas stove, 

the gas stove and LP gas cylinder must be stored outside 
in a well-ventilated place. 

 

OPERATION 

1.  Never  connect  your  gas  stove  to  an  LP  gas  cylinder 

without the regulator provided, and NEVER TO AN 
UNREGULATED LP GAS SUPPLY. The regulator 
supplied with the stove must be used. 

2.  Always leak test the LP gas cylinder to regulator 

connection when connecting the LP gas cylinder to the 
appliance. See “Leak Testing.” (Page 6) 

3.  Do not operate appliance if the smell of LP gas is 

present. Extinguish all flame and determine source of LP 
gas before proceeding. Do not ignite the appliance until 
the LP gas leak has been found and sealed. 

4.  Always shut off LP gas cylinder valve when the appliance 

is not in use. 

Содержание 9202-54

Страница 1: ...AME 3 DISCONNECT FROM FUEL SUPPLY 4 EVACUATE IMMEDIATELY 5 ALLOW GAS TO DISSIPATE 5 MINUTES BEFORE RELIGHTING THE APPLIANCE FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN FIRE OR EXPLOSION WHICH...

Страница 2: ...liquids in the vicinity of this or any other appliance DANGER CARBON MONOXIDE HAZARD THIS APPLIANCE CAN PRODUCE CARBON MONOXIDE WHICH HAS NO ODOR USING IT IN AN ENCLOSED SPACE CAN KILL YOU NEVER USE...

Страница 3: ...ly 8 20cm high 3 9 10cm diameter 3 The cylinder must be installed as per assembly instructions STORAGE 1 Store the LP gas cylinder outdoors in a well ventilated place 2 Do not store the LP gas cylinde...

Страница 4: ...1977 Canada CSA B96 5 The cylinder supply system must be arranged for vapor withdrawal 6 The cylinder must include a collar to protect the cylinder valve 7 The cylinder must be installed as per assem...

Страница 5: ...nd wheel Remove hose regulator assembly and replace with a new one 4 The pressure regulator is set at 11 inches WC water column and is for use with LP gas only The hose and hose couplings comply with...

Страница 6: ...eaks outdoors TO TEST FOR LEAKS 1 Extinguish any open flame or cigarettes in the area 2 Be sure that cylinder valve and gas grill valves are OFF 3 Connect LP gas cylinder See Hose and Regulator 4 Prep...

Страница 7: ...symptoms occur 1 You smell gas 2 Your gas stove does not reach temperature 3 Your gas stove heats unevenly 4 The burners make popping noises INSPECTING CLEANING 1 Turn off gas by closing the propane...

Страница 8: ...on the gas supply LIGHTING THE BURNER a Open gas stove lid and leave open b Push and turn control knob to HIGH c Push ignitor 3 or 4 times or use match to light d Burner should ignite within 5 second...

Страница 9: ...maintenance storage or transportation Remove regulator adapter hose and propane tank before storage or transportation 1 Lock lid in closed position with locking pins 2 Ensure regulator and legs are se...

Страница 10: ...OR FINISH If white oxidation spots appear wash the outside of the stove with a mild soap and water solution Rinse the surfaces thoroughly then wipe them with a cloth dipped in cooking oil to restore t...

Страница 11: ...ge 8 If burner lights successfully it is an ignitor issue See Ignitor not Working below 3 Follow Flickering Flame or Low Temperatures on HIGH setting solution above 4 Tighten the regulator hand wheel...

Страница 12: ...osts Removal or re installation costs Labor costs for installation and repair Cost of service calls Liability for indirect or consequential damages Gas stoves deemed to be used as a communal amenity o...

Страница 13: ...4 VACUER IMM DIATEMENT 5 PERMETTRE AU GAZ DE SE DISSIPER PENDANT 5 MINUTES AVANT D ALLUMER NOUVEAU L APPAREIL LE NON RESPECT DE CES INSTRUCTIONS PEUT CAUSER UN INCENDIE OU UNE EXPLOSION QUI POURRAIT...

Страница 14: ...T Ne pas entreposer ni utilizer d essence ni d autres vapeurs ou liquids inflammables proximit de cet appareil ou de tout autre appareil DANGER MONOXYDE DE CARBONE CETTE APPAREIL PEUT PRODUIRE DU MONO...

Страница 15: ...utilis e avec cet appareil doit avoir une capacit maximale 16 4 oz 5kg Taille approximative 8po 20cm de haut et 3 9po 10cm de diam tre 3 Le cylindre doit tre install conform ment aux instructions de m...

Страница 16: ...tation de la bonbonne doit permettre la vapeur de s chapper 6 La bonbonne doit tre munie d un rebord pour prot ger le robinet d arr t 7 La bonbonne doit tre install e conform ment aux instructions d a...

Страница 17: ...mplacer l assemblage du tuyau et du r gulateur avec un neuf 4 Le r gulateur de pression est r gl 11 po CE colonne d eau et convient seulement pour le gaz propane Le tuyau et les accouplements sont con...

Страница 18: ...ou d une flamme nue Effectuer le test d tanch it l ext rieur V RIFICATION DES FUITES DE GAZ 1 teindre toute flamme nue ou cigarette proximit 2 Assurer que les soupapes de la bonbonne et l appareil so...

Страница 19: ...e odeur de gaz 2 Votre po le n atteint pas la temp rature d sir e 3 La temp rature du po le n est pas uniforme 4 Les br leurs mettent des cr pitements INSPECTION ET NETTOYAGE 1 Fermer l alimentation e...

Страница 20: ...onne de gaz ALLUMAGE DU BR LEUR PRINCIPAL a Ouvrir le couvercle du gril gaz et laisser ouvert b Pousser et tourner le bouton de br leurs HIGH c Poussez le bouton d allumeur 3 ou 4 fois ou utilisez une...

Страница 21: ...tateur du r gulateur et la bouteille de propane avant l entreposage ou le transport 1 Verrouiller le couvercle en position ferm e l aide des goupilles de verrouillage 2 S assurer que les pieds et le r...

Страница 22: ...n blanches apparaissent laver l ext rieur du boitier avec de l eau et un d tergent doux Bien rincer les surfaces et les essuyer avec un chiffon imbib d huile de cuisson pour leur redonner leur lustre...

Страница 23: ...ton d allumage ne fonctionne pas ci dessous 3 Suivre la solution Flamme de br leur vacillante ou basse temp rature au r glage HIGH ci dessus 4 Serrer la roue main du r gulateur 5 Tester l tanch it des...

Страница 24: ...e main d uvre pour l installation et les r parations Co ts des appels de service Responsabilit pour les dommages indirects ou cons cutifs Les grils gaz pr vus pour l usage comme am nagement commun ou...

Страница 25: ...MEDIATAMENTE 5 PERMITE QUE EL GAS SE DISIPA POR 5 MINUTOS ANTES DE CONECTAR EL APARATO FALLO A CUMPLIR ESTAS PRECAUCIONES E INSTRUCCIONES PROVE DAS CON ESTOS FOGONES PUEDE RESULTAR EN SU MUERTE HERIDA...

Страница 26: ...na o otros liquidos con vapores inflamables cerca de este o cualquier Otro artefacto PELIGRO PELIGRO DE MONOXIDO DE CARBONO ESTA COCINA PUEDE PRODUCIR MONOXIDO DE CARBONO EL CUAL NO TIENE OLOR USO EN...

Страница 27: ...alto y 12 pulgadas 31 cm de di metro 3 El cilindro debe instalarse de acuerdo con las instrucciones de montaje ALMACENAMIENTO 1 Almacene el cilindro de gas LP en un exterior en un lugar bien ventilad...

Страница 28: ...CGA V 1 1977 EE UU y CSA B96 Canad 5 El sistema de suministro del cilindro debe estar acondicionado para recuperaci n de vapor 6 El cilindro debe incluir un collar para proteger la v lvula del cilindr...

Страница 29: ...de columna de agua y nicamente debe utilizarse con gas LP Los acoples entre manguera y manguera cumplen con la Norma CGA CAN 1 83 No se debe realizar ninguna modificaci n ni sustituci n 5 Proteja la m...

Страница 30: ...de fugas en un exterior PARA COMPROBAR SI HAY FUGAS 1 Apague cualquier llama expuesta o cigarrillo que haya en el rea 2 Aseg rese de que la v lvula del cilindro y las v lvulas de la cocina a gas est...

Страница 31: ...les 1 Siente olor a gas 2 Su cocina a gas no gana temperatura 3 Su cocina se calienta de manera irregular 4 Los quemadores emiten chasquidos INSPECCI N Y LIMPIEZA 1 Corte el suministro de gas cerrando...

Страница 32: ...nte la cubierta de la cocina y d jela abierta b Presione y haga girar una perilla de control hacia ALTA c Oprima el encendedor 3 o 4 veces o encienda con un fosforo d El quemador debe encenderse en un...

Страница 33: ...del regulador adaptador y el tanque de propano antes de almacenamiento o transporte 1 Cerrar la tapa en la posici n de cerrado con los pasadores de cerradura 2 Verificar que el accesorio de patas y re...

Страница 34: ...e xido lave la caja de cocci n por fuera con una soluci n de agua y jab n Enjuague bien las superficies y luego l mpielas utilizando un pa o humedecido en aceite de cocina para devolverles el brillo P...

Страница 35: ...cendedor no funciona a continuaci n 3 Siga la soluci n que aparece m s arriba en Llama parpadeante o Temperaturas bajas con control en ALTA 4 Ajuste la manivela del regulador 5 Compruebe si hay fugas...

Страница 36: ...s de devoluci n o reinstalaci n Costo de mano de obra por reinstalaci n o reparaciones Costo de llamadas de servicios t cnicos Responsabilidad por da os indirectos o consiguientes Cocinas a gas que se...