Brocade TurboIron 24X Series Hardware Installation Guide
Part Number: 53-1003053-03
Installing the TurboIron 24X
Attaching a PC or terminal
10G port LEDs should be lit while the device performs diagnostics. After the diagnostics are complete, the LEDs will be dark except for
those that are attached by cables to other devices.
If the links on these cables are good and the connected device is powered on, the link LEDs will light.
provides more details on
specific LED conditions after system start-up.
Observing the power status LEDs
lists the device LEDs that show power status.
The software regularly polls the hardware for power status information. You can display the status information from any management
session using the
show chassis
CLI command. In addition, the software automatically generates a Syslog message and SNMP trap if a
status change occurs.
Attaching a PC or terminal
To assign an IP address, you must have access to the
Command Line Interface (CLI)
. The CLI is a text-based interface that can be
accessed through a direct serial connection to the device or through Telnet connections.
You will need to assign an IP address using the CLI. You can access the CLI by attaching management station through a serial cable to
the Console port. After you assign an IP address, you can access the system through Telnet or
Brocade Network Advisor
.
Follow the steps to attach a management station using the serial port.
1.
Use a straight-through cable to connect a PC or terminal to the male DB-9 serial port connector.
NOTE
You need to run a terminal emulation program on the PC.
2.
Open the terminal emulation program and set the session parameters as follows:
•
Baud: 9600 bps
TABLE 2
Power LEDs
LEDs
Position
State
Meaning
Pwr (Power)
Left-most LED on the
front panel
On
The device is powered on and has enough
power to operate.
Off
The device is not powered on, or has been
powered on but does not have sufficient
power to operate.
AC OK
On power supply 1 front
panel
On
Power supply 1 is installed and is functioning
normally. Power supply 1 is located in the
right-hand bay (when you are facing the rear
of the device).
Off
Power supply 1 is not installed or is not
providing power.
AC OK
On power supply 2 front
panel
On
Power supply 2 is installed and is functioning
normally. Power supply 2 is located in the left-
hand bay (when you are facing the rear of the
device).
Off
Power supply 2 is not providing power.