background image

Fabric Watch User’s Guide

Glossary-3

Brocade 
Zoning

TM

A Brocade product that runs on Fabric OS and allows partitioning of the fabric 
into logical groupings of devices. Devices in a zone can only access and be 
accessed by devices in the same zone. See also Zone.

Buffer

-

to

-

buffer 

Flow Control

Management of the frame transmission rate in either a point-to-point topology or 
in an arbitrated loop. See also BB_Credit.

Cascade

Two or more interconnected fibre channel switches. SilkWorm 2000 switches can 
be cascaded up to 239 switches, with a recommended maximum of seven 
interswitch links (no path longer than eight switches). See also FabricISL.

Chassis

The metal frame in which the switch and switch components are mounted. 

Circuit

An established communication path between two ports. Consists of two virtual 
circuits capable of transmitting in opposite directions. See also Link.

Class 1

Service that provides a dedicated connection between two ports (also called 
connection-oriented service), with notification of delivery or nondelivery.

Class 2

Service that provides multiplex and connectionless frame switching service 
between two ports, with notification of delivery or nondelivery. 

Class 3

Service that provides a connectionless frame switching service between two ports, 
without notification of delivery or nondelivery of data. Can also be used to 
provide a multicast connection between the originator and recipients, with 
notification of delivery or nondelivery.

Class F

Connectionless service for control traffic between switches, with notification of 
delivery or nondelivery of data between the E_Ports.

Class of 
Service

A specified set of delivery characteristics and attributes for frame delivery.

Comma

A unique pattern (either 1100000 or 0011111) used in 8B/10B encoding to specify 
character alignment within a data stream. See also K28.5.

Community 
(SNMP)

A relationship between a group of SNMP managers and an SNMP agent, in which 
authentication, access control, and proxy characteristics are defined. See also 
SNMP.

CRC

Cyclic Redundancy Check; a check for transmission errors included in every data 
frame.

Credit

As applies to fibre channel, the number of receive buffers available for 
transmission of frames between ports. See also BB_CreditEE_Credit.

Cut

-through

A switching technique that allows the route for a frame to be selected as soon as 
the destination address is received. See also Route.

Data Word

Type of transmission word that occurs within frames. The frame header, data 
field, and CRC all consist of data words. See also FrameOrdered set
Transmission Word.

Defined Zone 
Configuration

The set of all zone objects defined in the fabric. May include multiple zone 
configurations. See also Enabled ConfigurationZone Configuration.

Disparity

The relationship of ones and zeros in an encoded character. “Neutral disparity” 
means an equal number of each, “positive disparity” means a majority of ones, 
and “negative disparity” means a majority of zeros.

DLS

Dynamic Load Sharing; dynamic distribution of traffic over available paths. 
Allows for recomputing of routes when an Fx_Port or E_Port changes status.

Содержание Brocade Fabric Watch

Страница 1: ...Publication Number 53 0000137 03 Brocade Fabric WatchTM User s Guide Version 3 0...

Страница 2: ...trademarks or service marks of and are used to identify products or services of their respective owners NOTICE THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT SET FORTH ANY WARRANTY EXPR...

Страница 3: ...Behavior Models 1 2 Range Threshold 1 2 Rising Falling Threshold 1 3 Change Monitor Threshold 1 4 Chapter 2 Installing Fabric Watch Installing through Telnet 2 1 Installing through Brocade Web Tools...

Страница 4: ...inuous Events 3 9 Alarms 3 9 SNMP Trap 3 9 Error Log Entry 3 10 Locking the Port Log 3 10 RAN 3 10 Email Alert 3 10 Configuring Thresholds and Alarms 3 10 Threshold Values 3 11 Threshold Area Values 3...

Страница 5: ...cade Fabric OS Procedures Guide Brocade Fabric OS Reference Brocade MIB Reference Brocade Web Tools User s Guide Brocade Zoning User s Guide Brocade QuickLoop User s Guide Brocade Fabric Watch User s...

Страница 6: ...onfiguration Output from the supportShow telnet command Detailed description of the problem Troubleshooting steps already performed Getting Software Updates Contact your switch supplier for software u...

Страница 7: ...based enterprise manager By modifying and uploading the Brocade Fabric WatchTM configuration file to the switch Brocade Fabric WatchTM monitors the following elements Fabric events such as topology r...

Страница 8: ...from the following website http www brocade com support mibs_Rsh Threshold Behavior Models The behavior models for thresholds are Range Rising falling Change monitor Range Threshold A range threshold...

Страница 9: ...ld A rising falling threshold tracks whether an element is on the desired side of a boundary It includes an upper and lower boundary and the buffer zones are always zero Events can be selected for tra...

Страница 10: ...change monitor threshold generates events whenever a counter value changes regardless of the type of change This type of threshold is usually used to indicate state changes such as zoning changes Not...

Страница 11: ...ollowing steps 1 Log onto the switch by telnet refer to Brocade Fabric OS User s Guide for details using an account that has administrative privileges 2 To determine whether a Fabric Watch license is...

Страница 12: ...the Location Address field for example http 111 222 33 1 and press Enter Brocade Web ToolsTM launches displaying the Fabric View 2 Click the Admin button on the relevant switch panel The logon window...

Страница 13: ...lsius RPM or unit of time Time base for counter used to compute rate of change for example events per minute Historical information about the last alarmed event generated User Interfaces Use either Br...

Страница 14: ...eshold and alarm configurations by uploading the configuration file from the switch to the host editing it in a text editor then downloading the modified file back to the switch You can then ensure a...

Страница 15: ...oundary Upper boundary Buffer size Alarm values Change Exceed Below Above In between Behavior type Classes Fabric and switch elements are organized into classes also known as Agents which are grouping...

Страница 16: ...itoring license has been purchased and turned on Note The EE filter is preconfigured with either a telnet command or Web Tools at run time Filter Monitors the filter counter for a given port Provides...

Страница 17: ...otocol error Monitors port protocol errors Invalid transmission word Monitors port invalid words Invalid CRC count Monitors port CRC errors Receive performance Monitors port receive performance Transm...

Страница 18: ...nges Monitors optical F FL_port state changes F FL_Port Copper Link failure count Monitors link failure of each copper F FL_port Loss of synchronization count Monitors copper F FL_port sync loss Loss...

Страница 19: ...eiver power Transmitter power Monitors GBIC transmitter power Current Monitors GBIC current ALPA CRC Counter Monitors all active ALPA devices on loop ports End to End CRC Counter Monitors CRC errors o...

Страница 20: ...ed Fabric Watch may raise an event such as a below event then the threshold is hidden and disabled When an item is added the threshold is displayed and enabled and Fabric Watch may raise an event Even...

Страница 21: ...above the upper boundary Accompanies a below or above event Changed Counter value has changed Alarms Each event can generate one or more alarms Fabric Watch supports the following types of alarms SNM...

Страница 22: ...Thresholds and Alarms The configuration of thresholds and alarms can be divided into two categories threshold values and threshold area values Note Timebase changes to thresholds in Env and GBIC agent...

Страница 23: ...the Transmit performance area Receive performance area Filter class Low boundary Minimum value An event is generated if the element value falls below this boundary High boundary Maximum value An even...

Страница 24: ...3 12 Fabric Watch User s Guide Using Fabric Watch 3...

Страница 25: ...e high boundary current value 5 Error s minute faulty 0x1003f2d0 tThad May 22 17 31 33 Error FW ABOVE 3 fopportSync003 3 is above high boundary current value 3 Error s minute faulty 0x1003f2d0 tThad M...

Страница 26: ...s envFan000 envFan002 Example 2 class name gbic area name Temp element index 001 00x threshold name is gbicTemp001 gbicTemp00x Table A 1 Fabric Watch Threshold Class Area Abbreviation Table Class name...

Страница 27: ...s State Loss of Sync Sync TX Performance TXPerf Invalid Words Words Fabric fabric Domain ID DI E port down ED Fabric login FL Fabric QL FQ Reconfigure FR GBIC change GS Segmentation SC Zoning change Z...

Страница 28: ...A 4 Fabric Watch User s Guide Example Error Message A...

Страница 29: ...ric attachment See also Topology ASIC Application Specific Integrated Circuit ATM Asynchronous Transfer Mode a transport used for transmitting data over LANs or WANs that transmit fixed length units o...

Страница 30: ...d switch elements Brocade ISL TrunkingTM A Brocade feature that enables distribution of traffic over the combined bandwidth of up to four ISLs between adjacent switches while preserving in order deliv...

Страница 31: ...nondelivery Class F Connectionless service for control traffic between switches with notification of delivery or nondelivery of data between the E_Ports Class of Service A specified set of delivery ch...

Страница 32: ...also EE_Credit Error As applies to fibre channel a missing or corrupted frame time out loss of synchronization or loss of signal link errors See also Loop Failure Exchange The highest level fibre cha...

Страница 33: ...ed on site FS Fibre Channel Service a service that is defined by fibre channel standards and exists at a well known address For example the Simple Name Server is a fibre channel service See also FSP F...

Страница 34: ...or more controllers See also RAID K28 5 A special 10 bit character used to indicate the beginning of a transmission word that performs fibre channel control and signaling functions The first seven bi...

Страница 35: ...t to point connection See also NL_Port Nx_Port Name Server Frequently used to indicate Simple Name Server See also SNS NL_Port Node Loop Port a node port that has arbitrated loop capabilities Used to...

Страница 36: ...ic can function within either a public or a private loop and can communicate with either private or public NL_Ports Public Device A device that supports arbitrated loop protocol can interpret 8 bit ad...

Страница 37: ...tocol and is controlled by software Switch Name The arbitrary name assigned to a switch Switch Port A port on a switch Switch ports can be E_Ports F_Ports or FL_Ports SWL Short Wavelength a type of fi...

Страница 38: ...for SCSI status before initiating ULP recovery Unicast The transmission of data from a single source to a single destination See also Broadcast Multicast Well known Address As pertaining to fibre cha...

Страница 39: ...ort 3 5 Environmental 3 5 F FL_Port copper 3 6 F FL_Port optical 3 6 Fabric 3 4 GBIC FINISAR Smart GBIC 3 7 Port 3 5 configuring modifying the configuration file 3 2 thresholds and alarms 3 10 continu...

Страница 40: ...ing to access Fabric Watch 3 2 SNMP trap 3 9 support technical iv supportShow telnet command iv T technical support iv telnet accessing Fabric Watch by 3 2 installing by 2 1 telnet commands supportSho...

Страница 41: ......

Отзывы: