3-10
Fabric Watch User’s Guide
Using Fabric Watch
3
RAN
RAJ sends alarm messages to the remote agent proxy server.
Note:
The RAN alert is only available if the optional Fabric Access license has been purchased
and turned on.
Email Alert
The Email Alert sends alarms to the corresponding email addresses at run time. The configured
email address applies to all areas within a class. See fwMailCfg in the Fabric OS Reference Guide.
Note:
This alert only works with firmware images that supports Web Tools.
Note:
Whenever the switch is fastbooted or rebooted the Email alert is disabled. The Email Alert
must be reset after the switch is fastbooted or rebooted.
Configuring Thresholds and Alarms
The configuration of thresholds and alarms can be divided into two categories: threshold values and
threshold area values.
Note:
Timebase changes to thresholds in Env and GBIC agents are disabled. Non-factory
timebase settings in configuration files for both of these thresholds will not have any effect.
The factory timebase will be used.
Threshold Values
Threshold values apply to the specific threshold. They are not stored in the configuration file, and
return to the default values if the switch is rebooted. The following threshold values can be
modified:
Status
Can be enabled or disabled. Enabled by default.
Behavior type
Allows setting of the event policy to triggered or continuous. Set to
triggered by default.
Behavior interval
The interval between the same type of alarm. Applies only to
continuous events. The default interval is 1 second.