Fabric Watch User’s Guide

Glossary-5

FC-SW-2

The second generation of the Fibre Channel Switch Fabric standard defined by 
ANSI. Specifies tools and algorithms for the interconnection and initialization of 
fibre channel switches in order to create a multi-switch fibre channel fabric. 

Fibre Channel 
Transport

A protocol service that supports communication between fibre channel service 
providers. See also FSP.

Fill Word

An IDLE or ARB ordered set that is transmitted during breaks between data 
frames to keep the fibre channel link active. 

Firmware

The basic operating system provided with the hardware.

FL_Port

Fabric Loop Port; a port that is able to transmit under fabric protocol and also has 
arbitrated loop capabilities. Can be used to connect an NL_Port to a switch. See 
also F_PortFx_Port.

FLOGI

Fabric Login; the process by which an N_Port determines whether a fabric is 
present, and if so, exchanges service parameters with it. See also PLOGI.

Frame

The fibre channel structure used to transmit data between ports. Consists of a 
start-of-frame delimiter, header, any optional headers, the data payload, a cyclic 
redundancy check (CRC), and an end-of-frame delimiter. There are two types of 
frames: Link control frames (transmission acknowledgements, etc.) and data 
frames.

FRU

Field-replaceable Unit; a component that can be replaced on site.

FS

Fibre Channel Service; a service that is defined by fibre channel standards and 
exists at a well-known address. For example, the Simple Name Server is a fibre 
channel service. See also FSP.

FSP

Fibre Channel Service Protocol; the common protocol for all fabric services, 
transparent to the fabric type or topology. See also FS.

FSPF

Fabric Shortest Path First; Brocade’s routing protocol for fibre channel switches.

Full-duplex

A mode of communication that allows the same port to simultaneously transmit 
and receive frames. See also Half-duplex.

Fx_Port

A fabric port that can operate as either an F_Port or FL_Port. See also F_Port
FL_Port.

G_Port

Generic Port; a port that can operate as either an E_Port or F_Port. A port is 
defined as a G_Port when it is not yet connected or has not yet assumed a specific 
function in the fabric.

GBIC

Gigabit Interface Converter; a removable serial transceiver module that allows 
gigabaud physical-level transport for fibre channel and gigabit ethernet.

Gbps

Gigabits per second (1,062,500,000 bits/second).

GBps

GigaBytes per second (1,062,500,000 bytes/second).

Half-duplex

A mode of communication that allows a port to either transmit or receive frames 
at any time, but not simultaneously (with the exception of link control frames, 
which can be transmitted at any time). See also Full-duplex.

Hard Address

The AL_PA that an NL_Port attempts to acquire during loop initialization.

HBA

Host Bus Adapter; the interface card between a server or workstation bus and the 
fibre channel network.

Содержание Brocade Fabric Watch

Страница 1: ...Publication Number 53 0000137 03 Brocade Fabric WatchTM User s Guide Version 3 0...

Страница 2: ...trademarks or service marks of and are used to identify products or services of their respective owners NOTICE THIS DOCUMENT IS FOR INFORMATIONAL PURPOSES ONLY AND DOES NOT SET FORTH ANY WARRANTY EXPR...

Страница 3: ...Behavior Models 1 2 Range Threshold 1 2 Rising Falling Threshold 1 3 Change Monitor Threshold 1 4 Chapter 2 Installing Fabric Watch Installing through Telnet 2 1 Installing through Brocade Web Tools...

Страница 4: ...inuous Events 3 9 Alarms 3 9 SNMP Trap 3 9 Error Log Entry 3 10 Locking the Port Log 3 10 RAN 3 10 Email Alert 3 10 Configuring Thresholds and Alarms 3 10 Threshold Values 3 11 Threshold Area Values 3...

Страница 5: ...cade Fabric OS Procedures Guide Brocade Fabric OS Reference Brocade MIB Reference Brocade Web Tools User s Guide Brocade Zoning User s Guide Brocade QuickLoop User s Guide Brocade Fabric Watch User s...

Страница 6: ...onfiguration Output from the supportShow telnet command Detailed description of the problem Troubleshooting steps already performed Getting Software Updates Contact your switch supplier for software u...

Страница 7: ...based enterprise manager By modifying and uploading the Brocade Fabric WatchTM configuration file to the switch Brocade Fabric WatchTM monitors the following elements Fabric events such as topology r...

Страница 8: ...from the following website http www brocade com support mibs_Rsh Threshold Behavior Models The behavior models for thresholds are Range Rising falling Change monitor Range Threshold A range threshold...

Страница 9: ...ld A rising falling threshold tracks whether an element is on the desired side of a boundary It includes an upper and lower boundary and the buffer zones are always zero Events can be selected for tra...

Страница 10: ...change monitor threshold generates events whenever a counter value changes regardless of the type of change This type of threshold is usually used to indicate state changes such as zoning changes Not...

Страница 11: ...ollowing steps 1 Log onto the switch by telnet refer to Brocade Fabric OS User s Guide for details using an account that has administrative privileges 2 To determine whether a Fabric Watch license is...

Страница 12: ...the Location Address field for example http 111 222 33 1 and press Enter Brocade Web ToolsTM launches displaying the Fabric View 2 Click the Admin button on the relevant switch panel The logon window...

Страница 13: ...lsius RPM or unit of time Time base for counter used to compute rate of change for example events per minute Historical information about the last alarmed event generated User Interfaces Use either Br...

Страница 14: ...eshold and alarm configurations by uploading the configuration file from the switch to the host editing it in a text editor then downloading the modified file back to the switch You can then ensure a...

Страница 15: ...oundary Upper boundary Buffer size Alarm values Change Exceed Below Above In between Behavior type Classes Fabric and switch elements are organized into classes also known as Agents which are grouping...

Страница 16: ...itoring license has been purchased and turned on Note The EE filter is preconfigured with either a telnet command or Web Tools at run time Filter Monitors the filter counter for a given port Provides...

Страница 17: ...otocol error Monitors port protocol errors Invalid transmission word Monitors port invalid words Invalid CRC count Monitors port CRC errors Receive performance Monitors port receive performance Transm...

Страница 18: ...nges Monitors optical F FL_port state changes F FL_Port Copper Link failure count Monitors link failure of each copper F FL_port Loss of synchronization count Monitors copper F FL_port sync loss Loss...

Страница 19: ...eiver power Transmitter power Monitors GBIC transmitter power Current Monitors GBIC current ALPA CRC Counter Monitors all active ALPA devices on loop ports End to End CRC Counter Monitors CRC errors o...

Страница 20: ...ed Fabric Watch may raise an event such as a below event then the threshold is hidden and disabled When an item is added the threshold is displayed and enabled and Fabric Watch may raise an event Even...

Страница 21: ...above the upper boundary Accompanies a below or above event Changed Counter value has changed Alarms Each event can generate one or more alarms Fabric Watch supports the following types of alarms SNM...

Страница 22: ...Thresholds and Alarms The configuration of thresholds and alarms can be divided into two categories threshold values and threshold area values Note Timebase changes to thresholds in Env and GBIC agent...

Страница 23: ...the Transmit performance area Receive performance area Filter class Low boundary Minimum value An event is generated if the element value falls below this boundary High boundary Maximum value An even...

Страница 24: ...3 12 Fabric Watch User s Guide Using Fabric Watch 3...

Страница 25: ...e high boundary current value 5 Error s minute faulty 0x1003f2d0 tThad May 22 17 31 33 Error FW ABOVE 3 fopportSync003 3 is above high boundary current value 3 Error s minute faulty 0x1003f2d0 tThad M...

Страница 26: ...s envFan000 envFan002 Example 2 class name gbic area name Temp element index 001 00x threshold name is gbicTemp001 gbicTemp00x Table A 1 Fabric Watch Threshold Class Area Abbreviation Table Class name...

Страница 27: ...s State Loss of Sync Sync TX Performance TXPerf Invalid Words Words Fabric fabric Domain ID DI E port down ED Fabric login FL Fabric QL FQ Reconfigure FR GBIC change GS Segmentation SC Zoning change Z...

Страница 28: ...A 4 Fabric Watch User s Guide Example Error Message A...

Страница 29: ...ric attachment See also Topology ASIC Application Specific Integrated Circuit ATM Asynchronous Transfer Mode a transport used for transmitting data over LANs or WANs that transmit fixed length units o...

Страница 30: ...d switch elements Brocade ISL TrunkingTM A Brocade feature that enables distribution of traffic over the combined bandwidth of up to four ISLs between adjacent switches while preserving in order deliv...

Страница 31: ...nondelivery Class F Connectionless service for control traffic between switches with notification of delivery or nondelivery of data between the E_Ports Class of Service A specified set of delivery ch...

Страница 32: ...also EE_Credit Error As applies to fibre channel a missing or corrupted frame time out loss of synchronization or loss of signal link errors See also Loop Failure Exchange The highest level fibre cha...

Страница 33: ...ed on site FS Fibre Channel Service a service that is defined by fibre channel standards and exists at a well known address For example the Simple Name Server is a fibre channel service See also FSP F...

Страница 34: ...or more controllers See also RAID K28 5 A special 10 bit character used to indicate the beginning of a transmission word that performs fibre channel control and signaling functions The first seven bi...

Страница 35: ...t to point connection See also NL_Port Nx_Port Name Server Frequently used to indicate Simple Name Server See also SNS NL_Port Node Loop Port a node port that has arbitrated loop capabilities Used to...

Страница 36: ...ic can function within either a public or a private loop and can communicate with either private or public NL_Ports Public Device A device that supports arbitrated loop protocol can interpret 8 bit ad...

Страница 37: ...tocol and is controlled by software Switch Name The arbitrary name assigned to a switch Switch Port A port on a switch Switch ports can be E_Ports F_Ports or FL_Ports SWL Short Wavelength a type of fi...

Страница 38: ...for SCSI status before initiating ULP recovery Unicast The transmission of data from a single source to a single destination See also Broadcast Multicast Well known Address As pertaining to fibre cha...

Страница 39: ...ort 3 5 Environmental 3 5 F FL_Port copper 3 6 F FL_Port optical 3 6 Fabric 3 4 GBIC FINISAR Smart GBIC 3 7 Port 3 5 configuring modifying the configuration file 3 2 thresholds and alarms 3 10 continu...

Страница 40: ...ing to access Fabric Watch 3 2 SNMP trap 3 9 support technical iv supportShow telnet command iv T technical support iv telnet accessing Fabric Watch by 3 2 installing by 2 1 telnet commands supportSho...

Страница 41: ......

Отзывы: