2

WARNING

Please take note that this manual uses the following symbols to emphasize particular information:

NOTE: Indicates supplementary information needed to fully complete an instruction.

CAUTION

Identifies an instruction which, if not followed, may severely damage the unit and/or its components.

ABOUT THIS  MANUAL

ABOUT THESE  UNITS

LIMITATION

For residential (domestic) installation only. Installation work and electrical wiring must be done by a qualified person(s) in accordance with 
all applicable codes and standards, including fire-rated construction codes and standards.

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE FOLLOWING:

1

.

  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.

  Before servicing or cleaning the unit, disconnect power cord from electrical outlet.

3.

  This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.

4.

  When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

5.

  Do not use this unit with any solid-state speed control device other than following controls: 

6.

  This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal safety. It must be plugged into a 

mating 3-prong grounding receptacle, grounded in accordance with the national electrical code and local codes and ordinances. Do 
not remove the ground prong. Do not use an extension cord.

7.

  Do not install in a cooking area or connect directly to any appliances.

8.

  Do not use to exhaust hazardous or explosive materials and vapors.

9.

  When performing installation, servicing or cleaning these units, it is recommended to wear safety glasses and gloves.

10. 

When applicable local regulation comprise more restrictive installation and/or certification requirements, the aforementioned 
requirements prevail on those of this document and the installer agrees to conform to these at his own expenses.

CAUTION

1.

  To avoid prematurate clogged filters, turn OFF the unit during construction or renovation.

2.

  Please read specification label on product for further information and requirements.

3.

  Be sure to duct air outdoor – Do not intake/exhaust air into spaces within walls or ceiling or into attics, crawl spaces, or garage. 

4.

  Intended for residential installation only in accordance with the requirements of NFPA 90B.

5.

  Do not run any air ducts directly above or closer than 2 ft  to any furnace or its supply plenum, boiler, or other heat producing appliance. 

If a duct has to be connected to the furnace return plenum, it must be connected not closer than 9’ 10” from this plenum connection to 
the furnace. 

6.

  The ductwork is intended to be installed in compliance with all local and national codes that are applicable.

7.

  When leaving the house for a long period of time (more than two weeks), a responsible person should regularly check if the unit 

operates adequately.

8.

  If the ductwork passes through an unconditioned space (e.g.: attic), the unit must operate continuously except when performing 

maintenance and/or repair. Also, the ambient temperature of the house should never drop below 65°F.

U

NIT

M

AIN

 C

ONTROL

A

UXILIARY

 C

ONTROLS

ERV100SP

VT8W, VT7W, VT4W 

OR

 VT6W

VB60W 

AND

 59W

ERV100S

VT7W, VT4W 

OR

 VT6W

VB20W 

AND

 59W

    WARNING

Identifies an instruction which, if not followed, might cause serious personal injuries including possibility of death.

!

Содержание ERV100S

Страница 1: ...irements only when used in Canada 22634 rev 05 INSTALLATION GUIDE FOR BROAN ERV100S AND ERV100SP RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS Model ERV100S VB0198 Model ERV100SP VB0197 Broan NuTone LLC Hartford Wisconsin www broan com 800 543 3055 REGISTER YOUR PRODUCT ONLINE AT www broan com register For additional information visit www broan com ...

Страница 2: ...st hazardous or explosive materials and vapors 9 When performing installation servicing or cleaning these units it is recommended to wear safety glasses and gloves 10 When applicable local regulation comprise more restrictive installation and or certification requirements the aforementioned requirements prevail on those of this document and the installer agrees to conform to these at his own expen...

Страница 3: ...LS 13 16 3 1 BOOTING SEQUENCE 13 3 1 1 ERV100SP UNIT BOOTING SEQUENCE 13 3 1 2 ERV100S UNIT BOOTING SEQUENCE 13 3 2 ERV100SP UNIT INTEGRATED DEFROST CONTROL 14 3 3 ERV100S UNIT INTEGRATED CONTROL 14 3 4 SETTING EXTENDED DEFROST FOR ERV100S UNIT 14 3 5 ELECTRICAL CONNECTION TO WALL CONTROLS 15 16 3 5 1 ELECTRICAL CONNECTION TO VT8W MAIN WALL CONTROL 16 3 5 2 ELECTRICAL CONNECTION TO VT7W MAIN WALL ...

Страница 4: ... the register located in the lowest liveable level Homes with more than one level require at least one exhaust register at the highest level See figure at right 1 1 2 CENTRAL DRAW POINT CONNECTION TO A FORCED AIR SYSTEM Stale air coming from the registers located at the highest level of the house is exhausted to the outdoors Fresh air from outdoors is filtered and supplied to the return plenum or ...

Страница 5: ...r runs when the unit is in operation but we recommend it VH0094 2 INSTALLATION 2 1 INSPECT THE CONTENTS OF THE BOX Inspect the exterior of the unit for shipping damage Ensure that there is no damage to the door door hinges power cord etc Open the unit door and inspect the interior of the unit for damage Ensure that energy recovery core core filters insulation dampers etc are all intact 2 2 UNIT PR...

Страница 6: ...ire hazards Allow for a power source within 3 feet standard 3 prong grounding outlet Mount brackets to ceiling or joists To ease the brackets location use the template printed on the cardboard filler located in the unit box See below WARNING To ensure occupants safety ensure the brackets are mounted to solid surface e g concrete ceiling joists Hang the unit using 2 included brackets See below VO02...

Страница 7: ...lip the other side of unit onto the brackets 2 places WARNING Ensure the unit is completely held by the brackets before continuing the installation VD0330 NOTE The unit can also be hung using 4 hooks shaded part in illustration at right chains springs and screws kit sold separately part no V61239 CAUTION Make sure the unit is level ...

Страница 8: ...sition the registers as far from the stairway as possible and in such a way that the air circulates in all the lived in spaces in the house If a register is installed in the kitchen it must be located at least 4 feet from the range Install the registers 6 to 12 inches from the ceiling on an interior wall OR install them in the ceiling Fresh air distribution ductwork Install the fresh air distribut...

Страница 9: ...dler blower operation see Section 4 Method 2 Return side connection exclusively for ERV100SP unit only Cut an opening into the furnace return duct not less than 10 feet from the furnace air handler A B Connect this opening to the Fresh air to building port of the ERV see figure at right NOTE For Method 2 it is not essential that the furnace air handler runs when the unit is in operation but we rec...

Страница 10: ...to synchronize the furnace blower operation with the unit operation but we recommend it CAUTION When performing duct connections to the furnace supply duct this duct must be sized to support the additional airflow produced by the ERV Also use a steel duct For a Return Return installation the furnace blower must be in operation when the ERV is in operation VJ0115 B A VJ0114 B A STEEL DUCT MINIMUM 1...

Страница 11: ...ver the joint and tuck in between the inner and outer rings of the double collar then pull down the vapor barrier shaded part in illustrations below over the insulation and tuck in between the inner and outer rings Apply duct tape to the joint outer ring and vapor barrier making an airtight seal Avoid compressing the insulation when pulling the tape tightly around the joint Compressed insulation l...

Страница 12: ...h efficiency furnace vent central vacuum vent Gas meter exhaust gas barbecue grill Any exhaust from a combustion source Garbage bin and any other source of contamination VD0028 EXHAUST HOOD INTAKE HOOD TAPE AND DUCT TIE 18 6 18 18 6 6 Ø OPTIONAL DUCT LOCATION 2 9 INSTALLING TANDEM TRANSITION KIT If desired a Tandem transition kit can be used instead of 2 exterior hoods The joist opening needed to ...

Страница 13: ...page 22 for further details 3 1 BOOTING SEQUENCE During the booting sequence the integrated defrost control LED 1 in above illustration will be OFF for 3 seconds and then will turn RED for the rest of the booting sequence approximately 15seconds DuringthisREDlightphase theunitischeckingand resetting the motorized damper position Once the motorized damper position completely set the booting sequenc...

Страница 14: ...cycle choice to be kept in memory if a power failure occurs during this time delay when the power returns the unit resume to its previous setting 3 2 ERV100SP UNIT INTEGRATED DEFROST CONTROL After the booting sequence is done the LED 1 will light and stay lit to show in which defrost cycle the unit is set Use the push button 2 to change the defrost cycle of the unit see table at right LED COLOR DE...

Страница 15: ...e correctly inserted in their corresponding holes in the terminal block A wire is correctly inserted when its orange receptacle is lower than another one without wire On illustration at right wire A is correctly inserted but not wire B Splice back the end of the cable to access the 4 wires Strip the end of each wire Connect each wire to its corresponding terminal YELLOW wire to Y RED wire to R GRE...

Страница 16: ... 5 C 41 F C O M F O R T Z O N E 20 C 4 F OFF MIN MAX X X X X X 01 9 8 VE0370 3 5 5 ELECTRICAL CONNECTION TO OPTIONAL AUXILIARY WALL CONTROLS 59W ALL UNITS VB60W ERV100SP UNIT ONLY AND VB20W ERV100S UNIT ONLY NOTE If an optional auxiliary wall control is activated this control will override the main wall control commands Once the wall control s connections have been made and checked close the unit ...

Страница 17: ...W R G Y W R Y R G Y C THERMOSTAT TERMINAL 4 WIRES 2 WIRES heating only wiring nuts FURNACE 24 VOLT TERMINAL BLOCK 2 WIRES COOLING SYSTEM NO NC C UNIT TERMINAL CONNECTOR NO C NC I OC OL Y R G B VE0108A 5 SPEED SELECTION The factory set high speed value for theses units is 100 CFM and low speed value is approximately 50 CFM To change these values the transformer wire taps connections must be changed...

Страница 18: ...LASS 2 L OW V OLTAGE F IELD W IRING O VERRIDE SWITCH OPTIONAL F IELD WIRING REMOTE CONTROL F URNACE BLOWER INTERLOCK OPTIONAL B G R R G BK Y Y OL OC I J14 10 9 8 7 6 5 4 3 2 1 J20 1 2 J13 ICP A1 E LECTRONIC A SSEMBLY 1 2 3 4 5 J12 J11 1 2 4 3 2 1 J9 J10 2 1 F1 3A 3AG T YPE 3 2 1 JU1 M H 4 3 2 1 5 J8 J5 J7 1 1 2 2 3 J6 1 2 J4 1 2 3 2 1 5 4 3 2 1 1 2 J3 J2 J1 M3 A2 T HERMISTOR D AMPER E LECTRONIC A ...

Страница 19: ...small plastic plugs included in the hardware kit 6 Write the required air flow information on a label and stick it near the unit for future reference date maximum speed air flows your name phone number and business address NOTE The unit is considered balanced even if there is a difference of 10 cfm between the two air flows VP0009 VJ0116 EXHAUST AIRFLOW FRESH AIRFLOW LOW HIGH LOW HIGH VP0025A VD03...

Страница 20: ...20 8 SERVICE PARTS VL0075 10 2 3 4 5 6 7 8 9 13 12 16 7 17 21 1 11 19 14 15 18 20 ...

Страница 21: ... F ILTERS 2 V21030 1 1 18 ERV C ORE SV61223 1 1 19 C ORE L OCKING D EVICE K IT SV61237 1 1 20 5 M ETAL P ORT K IT FOR W ARM S IDE SV61217 2 2 21 D OOR M ETAL H INGES K IT 2 SV61228 2 2 T ERMINAL C ONNECTOR SV16416 1 1 C OLD S IDE T HERMISTOR K IT SV61221 1 O PTIONAL H ARDWARE K IT V61239 1 1 N OT SHOWN 8 SERVICE PARTS CONT D R EPLACEMENT P ARTS AND R EPAIR In order to ensure your ventilation unit ...

Страница 22: ...push button to restart unit Check for the door magnet to be properly seated onto the door If not correct the situation close the door and push once on the integrated push button to restart unit Ensure J11 connector is properly connected and its wires are not damaged If not correct the situation close the door and push once on the integrated push button to restart unit For all units Using a flat bl...

Страница 23: ...All units Unit not compatible with control The wires may be in reverse position The wires may be misconnected The wires may be broken Defective wall control Press on the integrated push button until the LED turns off Check table on page 2 for control compatibility Ensure that the color coded wires have been connected to their appropriate places Ensure the wires are correctly connected Inspect ever...

Страница 24: ...ks plug back supply motor to J4 connector and exhaust motor to J5 connector then check for supply motor capacitor validity Plug supply motor capacitor to J7 connector and exhaust motor capacitor to J6 connector If the LED flashes RED the supply motor capacitor is defective If there is no change the PCB is defective Plug exhaust motor to J4 connector and supply motor to J5 connector If supply motor...

Отзывы: