8
4. PREPARE THE HOOD (
CONT
'
D
)
DUCTED INSTALLATION ONLY:
Remove 3¼” x 10” vertical,
3¼” x 10” horizontal,
or 7-inch round
knockout plate
as appropriate for your ducting
method.
7” ROUND KNOCKOUT
PLATE (
ALSO
REMOVE
VERTICAL
KNOCKOUT
PLATE
)
3¼”
X
10”
VERTICAL
KNOCKOUT
PLATE
3¼”
X
10”
HORIZONTAL
KNOCKOUT
PLATE
Attach
3¼” x 10” Damper Assembly
(if using 3¼” x 10” duct; shaded
part in illustration at right) or
7” Round Duct Plate
(if using 7-inch
round duct) over the knockout
opening.
NOTES: To accommodate off-center
ductwork, the 7” round duct plate
can be installed up to 1/2” on either
side of the hood center.
Install the 3¼” x 10” damper
assembly with the
Damper Flap
Pivot
nearest the
Top/Back Edge
of Hood
.
7” ROUND
DUCT
PLATE
SCREWS
3¼”
X
10”
DAMPER
ASSEMBLY
TOP/BACK
EDGE OF
HOOD
DAMPER
FLAP
PIVOT
SCREWS
Purchase two non-ducted filters
(model HPF24 for 24” width hood or
HPF30 for 30” width hood) from your
local distributor or retailer. Attach
the non-ducted filters following
instructions packed with the
non-ducted filters, then go step 5
INSTALL THE HOOD on next page.
NON-DUCTED INSTALLATION ONLY:
RECIRCULATION
COVER PLATE
SCREWS
Remove 3 screws retaining the
recirculation cover plate (shaded
part in illustration at right) to the
hood. Discard this plate with its
screws.