Broan 1103435 Скачать руководство пользователя страница 8

Overture

TM

 WALL CONTROL

INCLUDED

Wall Control Part No. 1103434
User Manual
Quick Start Guide
Note: Wall plate not included – Use Broan Part No.
S97012925 (or equivalent)

1103414C

For Warranty Statement, Service Parts, Technical 
Support, or to Register your product, please visit our 
website or call: In the United States - Broan-NuTone.com
800-558-1711. In Canada - Broan-NuTone.ca
877-896-1119

CONTROL SPECIFICATIONS

• cULus 

Listed

•  120 VAC 60 Hz Line Power
•  Maximum load ½ HP Motor, 15A Resistive,

15A Inductive, 3A Incandescent, 0.6A Electronic Ballast

•  When used in combination with fan/light fi xtures 

that are switched together, the device is rated for the 
following lamps: 360W Incandescent, 72W LED, or 
72W CFL

•  Limits the maximum current to 15 Amps for each 

output and for the entire output.

•  For Control of Electronic Ballast, CFLs, LED and LED 

lamps or the equivalent

•  Typical Wire Sizes: 12AWG (MAX) or 14AWG solid 

copper wire rated for at least 90°C

•  Operating temperature: 32-95°F (0-35°C)
•  Purpose of Control: Operating Control
•  Rated impulse voltage: 2500 V

SAFETY

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1.  Before installing the wall control, switch power off at 

the service panel and lock the service disconnecting 
means to prevent power from being switched on 
accidentally. When the service disconnecting means 
cannot be locked, securely fasten a prominent warning 
device, such as a tag, to the service panel. CAUTION: 
Risk of Electric Shock - More than one disconnect 
switch may be required to de-energize the equipment 
before servicing.

2. All electrical work must be done in accordance with 

local codes, ordinances, or National Electrical Code, 
as applicable, including fi re-rated construction codes 
and standards. FOR SAFETY, THIS PRODUCT MUST 
BE GROUNDED. If you are unfamiliar with methods 
of installing electrical wiring, secure the services of a 
qualifi ed electrician.

3.  Use copper wire only.
4.  WARNING: This device shall not be used in combination 

with a wall switch controlling a receptacle.

5. Install only in a UL Listed junction box sized

2.0 x 3.0 x 3.0 in. (50.8 x 76.2 x 76.2 mm) or larger, with 
a minimum volume of 18.0 in

3

 (295 CM

3

) for 14AWG 

wiring and 20.0 in

3

 (328 CM

3

) for 12AWG wiring.

6.  This control requires a neutral wire for operation.
7. When cutting or drilling into wall or ceiling, do not 

damage electrical wiring or other hidden utilities.

8. To prevent serious injury from electrical shock or 

damage to electrical components - DO NOT WIRE 
HOT!

9. The automatic operation feature is Type 1.C action, 

according to UL 60730-1.

10. The enclosure protection rating is IP30.
11. The product is Pollution Degree 2, which is intended 

to be used in a household environment or similar.

12. The devices are not intended for use in locations 

where the temperature may be less than actual room 
conditions, such as unheated warehouses or garages.

13. Avoid water and wet locations. Keep the device 

away from water, fi re, excessive humidity, or hot 
environments.

14. Do not use the device where wireless devices are 

not allowed.

15. Do not attempt to disassemble, repair, or modify 

the device. Don’t disassemble the product, or make 
repairs yourself. You run the risk of electric shock 
and voiding the limited warranty. If you need service, 
please contact us.

16. Note: When power is applied, the Wall Control 1103434 

may require approximately 30 seconds to boot up and 
be ready to function.

17. Please read and follow the above safety information 

when operating the device. We cannot guarantee that 
no accidents or damage will occur due to the improper 
use of the device. Please use this product with care 
and operate at your own risk.

Warranty is void if miswired.

INSTALLATION

NOTE: This control requires a 120 VAC source (hot and 
neutral) in the switch box to operate the wall control.
1.  Turn off the power and lockout the service panel before 

wiring the control.

2. Location Notes:
  a. For bathroom applications, the control should 

be placed at a level to detect humidity. Placing the 
control directly above a heater or near drafts is NOT 
recommended.

 

b. For bathroom applications, the Wall Control should 
be placed in close proximity to the shower/tub/sink/
etc. (the main source of humidity/steam/VOC) and at 
sink height or higher for effective monitoring of your 
indoor air quality.

  c. Place your Wall Control within the range of your 

Wi-Fi router or access point (approximately 100 feet). 

 

d. Avoid physical obstructions and radio interference 
in the surrounding area.

3.  Install the wall control in at least a 3" deep switch box 

for #14 AWG wire or at least a 3 ½" deep switch box for 
#12 AWG wire. The control can be installed in either a 
metal outlet box or a plastic outlet box.

4.  Attach the incoming power line and ventilator power 

line to switch box. It may be necessary to use two 
side knockouts for some applications. Use proper 
connectors. Provide 6" leads inside box and ventilation 
product.

5. Make electrical connections following the diagrams 

provided on the last page or in the Broan-NuTone 
Overture

TM

 app. Use wire nuts. Make sure both the 

control and the ventilator are properly grounded. Wire 
terminals accept up to #12 AWG MAX solid wire.

  a. Loosen screw terminals.
  b. Strip wire 0.275" and insert the bare wire into the 

screw terminal opening.

  c. Tighten the terminal screw, making sure wire

remains under the clamp. Torque the terminal screws to
3.5 in-lbs (.4 N-m).

  d. Note: Do not reuse wire formed into a “J” loop or 

wrapped around screw threads. The screw terminal 
is designed for the straight insertion of stripped wire 
for proper mechanical and electrical connection.

6.  Tuck wires in and fasten control to switch box using 

attached screws. Verify wall control orientation before 
installation. Note “TOP” direction shown on the wall 
control label.

7.  Attach switch plate (not included) using color-matched 

oval head screws.

8.  Download the Broan-NuTone Overture

TM

 App for step by 

step set-up instructions to connect your Wall Control 
to the Overture

TM

 system. Scan QR code to go to App 

Store.

Regulatory Information

The Overture

TM 

Wall Control 1103434 is certified to 

comply with applicable FCC and IC rules and regulations 
governing RF and EMI emissions. Refer to 1103434. 
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This 
device may not cause harmful interference, and (2) This 
device must accept any interference received, including
interference that may cause undesired operation. The 
distance between user and device should be no less 
than 20 cm.

FCC Notice

This equipment has been tested and found to comply with 
the limits for a Class B digital device, pursuant to Part 15 
of the FCC Rules. These limits are designed to provide 
reasonable protection against harmful interference in 
a residential installation. This equipment generates, 
uses, and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions 
may cause harmful interference to radio communications. 
However, there is no guarantee that interference will 
not occur in a particular installation. If this equipment 
does cause harmful interference to radio or television
reception, which can be determined by turning the 
equipment off and on, the user is encouraged to try to 
correct the interference by one or more of the following 
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and 

receiver.

• Connect the equipment into an outlet on a circuit 

different from that to which the receiver is connected.

• Consult the dealer or an experienced radio/TV

technician to help.

Changes or modifi cations not expressly approved by the 
party responsible for compliance could void the user’s 
authority to operate the equipment.

ISED Compliance Statement

This device contains licence-exempt transmitter(s)/
receiver(s) that comply with Innovation, Science and 
Economic Development Canada’s licence-exempt RSS(s). 
Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including 

interference that may cause undesired operation of 
the device.

The Bluetooth® word mark and logos are registered 
trademarks owned by Bluetooth SIG, Inc. and any use 
of such marks by Broan-NuTone LLC is under license. 
Other trademarks and trade names are those of their 
respective owners.

The Android robot is reproduced or modifi ed from work 
created and shared by Google and used according to 
terms described in the Creative Commons 3.0 Attribution 
License.

Regulatory ID for 1103434 Overture

TM

 Wall Control

FCC ID: 2ADLL-1103434
IC: 2143B-1103434
M a d e   i n   C h i n a   t o   t h e   q u a l i t y   s t a n d a r d s   a n d
specifi cations of 
Broan-Nutone LLC Hartford, Wisconsin
www.broan-nutone.com 800-558-1711
Venmar Ventilation ULC Drummondville Quebec Canada 
www.broan-nutone.ca 877-896-1119

For more information and user manuals scan QR code 
below.

1103414_C.indd   1

2021-05-21   15:46:27

Содержание 1103435

Страница 1: ...ble protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfe...

Страница 2: ...une ventilation adéquate pour effectuer un suivi optimal de la qualité de l air Installer le capteur directement derrière une commode un divan etc l empêchera de profiter d une ventilation adéquate b Dans une salle de bain le capteur doit être installé près de la douche baignoire lavabo etc la source principale d humidité de vapeur de COV et à la hauteur du lavabo ou plus haut pour un suivi effica...

Страница 3: ...tamentesobreuncalentadornicercadecorrientes de aire Los lugares ideales para los sensores en sala son las recámaras las salas de estar los cuartos de estudio los lavaderos etc Asegúrese de que el sensor en sala posea un caudal de aire adecuado para una supervisión de alto rendimiento Una colocación directa detrás de un tocador un sofá etc impedirá un caudal de aire adecuado b En aplicaciones para ...

Страница 4: ...insert the bare wire into the screw terminal opening Make sure the wire is seated as far into the terminal is possible b Release the wire release mechanism making sure wire remains under the clamp c Note Do not reuse wire formed into a J loop or wrapped around screw threads The wire terminal is designed for the straight insertion of stripped wire for proper mechanical and electrical connection 5 R...

Страница 5: ...e correctement à la terre la prise intelligente et le système d air frais Les bornes sont compatibles avec les fils massifs ou toronnés de calibre 20 AWG à 16 AWG cotés pour au moins 75 C a Dénuder le fil de 0 5 po appuyer sur le mécanisme de relâchement du fil et insérer le fil dénudé dans l ouverture du bornier à vis S assurer que le fil soit installé le plus loin possible dans le bornier b Relâcher ...

Страница 6: ...ma página o según los diagramas de la aplicación Broan NuTone OvertureTM con el cableado adecuado para la aplicación Use tuercas para cable Asegúrese de que tanto el enchufe inteligente como el sistema de aire fresco estén bien conectados a tierra Los terminales de cable aceptan cable sólido o trenzado desde 20 AWG hasta 16 AWG apto para al menos 75 C a Pele el cable hasta 0 5 pulg presione el mec...

Страница 7: ... APPORT D AIR UNIVERSEL REGULADOR DE TIRO PARA AIRE DE REPOSICIÓN 24V TRANSFORMER TRANSFORMATEUR TRANSFORMADOR BLACK NOIR NEGRO LINE SOUS TENSION LINEA WHITE BLANC BLANCO COMMON NEUTRE NEUTRO GREEN VERT VERDE GROUND MISE À LA TERRE TOMA DE TIERRA 24V CORDED OPTION OPTION AVEC CORDON D ALIMENTATION OPCIÓN CON CABLE DE ALIMENTACIÓN 24V 24V MAKE UP AIR DAMPER DISPOSITIF D APPORT D AIR UNIVERSEL REGUL...

Страница 8: ...uter or access point approximately 100 feet d Avoid physical obstructions and radio interference in the surrounding area 3 Install the wall control in at least a 3 deep switch box for 14 AWG wire or at least a 3 deep switch box for 12 AWG wire The control can be installed in either a metal outlet box or a plastic outlet box 4 Attach the incoming power line and ventilator power line to switch box I...

Страница 9: ...ins 7 6 cm 3 po pour fils de calibre 14 AWG ou d au moins 8 9 cm 3 po pourfilsdecalibre12AWG Laboîteélectrique peut être en métal ou en plastique 4 Brancher le fil d alimentation et le fil du ventilateur sur la boîte de jonction Dans certains cas il faudra utiliserdeuxentréesdéfonçables Utiliserdesserre fils adaptés Laisser une longueur de 15 cm 6 po à tous les fils dans la boîte de jonction 5 Brancherl...

Страница 10: ...en el área circundante 3 Instaleelcontroldeparedenunacajadeseccionamiento de al menos 3 pulg 7 6 cm de profundidad para cable AWG 14 o de al menos 3 pulg 8 9 cm de profundidad para cable 12 AWG El control se puede instalar en una caja de salida metálica o en una caja de salida plástica 4 Conecte la línea de alimentación entrante y la línea de alimentación del ventilador con la caja de seccionamien...

Страница 11: ...OURNIE AU BOÎTIER DE COMMUTATION PUISSANCE FOURNIE AU VENTILATEUR OPTION SELON LE MODÈLE R M N MISE À LA TERRE BLA N MISE À LA TERRE BLA ENTRÉE 120 VCA R BLA N SCHÉMA GÉNÉRIQUE BLA MISE À LA TERRE N N SCHÉMAS ÉLECTRIQUES BIAQWC100P L N IN S2S1 L N IN S2 S1 OPTION SELON LE MODÈLE M NEG TIERRA CAJA DE SECCIONAMIENTO CAJA DE SECCIONAMIENTO BLNC VENTILADOR VENTILADOR NEG TIERRA BLNC ENTRADA 120 VCA EN...

Отзывы: