53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
switchShow
The
switchShow
command can be especially helpful in monitoring the health of the device. This command displays
status, identification, and configuration information on the chassis and installed blades and ports. The following example
shows output from this command.
NOTE
The following
switchShow
output has been truncated to reduce duplicate information.
chassisX6-8:admin> switchshow
switchName: switch1_SW
switchType: 166.0
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 1
switchId: fffc01
switchWwn: 10:00:00:25:f8:f1:15:80
zoning: ON (MPR4k)
switchBeacon: OFF
FC Router: OFF
FC Router BB Fabric ID: 128
Address Mode: 0
Fabric Name: BB1
HIF Mode: OFF
Index Slot Port Address Media Speed State Proto
============================================================
0 3 0 010000 id N32 Online FC F-Port 86:0d:00:11:0d:06:00:00
1 3 1 010100 id N32 Online FC F-Port 86:24:00:11:0d:07:00:00
2 3 2 010200 id N32 Online FC F-Port 86:0c:00:11:0d:05:00:00
3 3 3 010300 id N32 Online FC F-Port 86:25:00:11:0d:08:00:00
4 3 4 010400 id N32 Online FC F-Port 21:00:00:24:ff:90:55:30
5 3 5 010500 id N32 Online FC F-Port 21:00:00:24:ff:90:55:31
6 3 6 010600 id N32 Online FC F-Port 21:00:00:24:ff:90:55:9e
7 3 7 010700 id N32 ONline FC F-Port 21:00:00:24:ff:90:55:9f
8 3 8 010800 id N32 Online FC E-Port 10:00:00:27:f8:f2:c8:b8
9 3 9 010900 id N32 Online FC E-Port 10:00:00:27:f8:f2:c6:b8 "ras010" (Trunk master)
10 3 10 010a00 id N32 Online FC E-Port 10:00:00:27:f8:f2:c7:b8 "ras010" (Trunk master)
11 3 11 010b00 id N32 Online FC E-Port 10:00:00:27:f8:f2:c8:b8 "ras010" (Trunk master)
(output truncated)
tempShow
Use the
tempShow
command to display temperature readings of blade temperature sensors. The command displays the
following information:
53-1004105-13
93
Broadcom
Содержание Brocade X6-8 Director
Страница 207: ......