53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
•
Local CP state (slot number and CP ID), warm or cold, recovering or recovered.
•
Remote CP state (slot number and CP ID).
•
High Availability (enabled or disabled).
•
Heartbeat (up or down).
•
Health of standby CP.
•
HA synchronization status.
The following is an example of
haShow
output:
chassisX6:admin> hashow
Local CP (Slot 1, CP0): Active, Warm Recovered
Remote CP (Slot 2, CP1): Standby, Healthy
HA enabled, Heartbeat Up, HA State synchronized
Note the following about this output:
•
A warm recovery typically does not disrupt traffic flow.
•
A cold recovery is usually a result of a reboot of the active CP, which disrupts traffic.
•
A lack of HA synchronization can be related to a firmware download in progress or that the device is recovering from a
reboot or power-cycle.
historyShow
Use the
historyShow
command to display the entire history log, which includes insertion and removal events for field-
replaceable units (FRUs), such as blades, power supplies, fans, and world wide name (WWN) cards.
The following is an example of
historyShow
output:
chassisX6-8:admin> historyshow
CORE BLADE Slot 7 Inserted at Mon Jun 13 13:58:38 2016
Factory Part Number: 60-1003323-01
Factory Serial Number: DYH0339L00D
POWER SUPPLY Unit 1 Inserted at Mon Jun 13 13:59:09 2016
Factory Part Number: 23-0000163-01
Factory Serial Number: DUE2M03M04P
POWER SUPPLY Unit 2 Inserted at Mon Jun 13 13:59:09 2016
Factory Part Number: 23-0000161-01
Factory Serial Number: DUC2M35L0CL
(output truncated)
SW BLADE Slot 3 Inserted at Mon Jun 13 13:59:12 2016
Factory Part Number: 60-1003336-01
Factory Serial Number: EAL0338L006
FAN Unit 1 Inserted at Mon Jun 13 13:59:13 2016
Factory Part Number: 60-1003203-03
Factory Serial Number: DYL0329L014
FAN Unit 2 Inserted at Mon Jun 13 13:59:13 2016
Factory Part Number: 60-1003203-03
Factory Serial Number: DYL0329L01A
(output truncated)
53-1004105-13
89