53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
CP0
Ethernet IP Address: 192.0.2.2
Ethernet Subnetmask: 255.255.255.0
Host Name: cp0
Gateway IP Address: 192.0.2.6
CP1
Ethernet IP Address: 192.0.2.3
Ethernet Subnetmask: 255.255.240.0
Host Name: cp1
Gateway IP Address: 192.0.2.6
Backplane IP address of CP0 : 192.0.2.4
Backplane IP address of CP1 : 192.0.2.5
IPv6 Autoconfiguration Enabled: Yes
Local IPv6 Addresses:
chassis 0 stateless fd00:60:69bc:63:205:1eff:fe39:e45a/64 preferred
chassis 0 stateless fec0:60:69bc:63:205:1eff:fe39:e45a/64 preferred
cp 0 stateless fd00:60:69bc:63:205:1eff:fe40:6230/64 preferred
cp 0 stateless fec0:60:69bc:63:205:1eff:fe40:6230/64 preferred
cp 1 stateless fd00:60:69bc:63:205:1eff:fe39:ff2a/64 preferred
cp 1 stateless fec0:60:69bc:63:205:1eff:fe39:ff2a/64 preferred
IPv6 Gateways:
cp 0 fe80:60:69bc:63::3
cp 0 fe80:60:69bc:63::1
cp 0 fe80:60:69bc:63::2
cp 1 fe80:60:69bc:63::1
cp 1 fe80:60:69bc:63::2
cp 1 fe80:60:69bc:63::3
5. Display and record the manufacturer serial numbers.
Enter
chassisShow
, and then copy the command output into the
config-miscinfo.txt
file.
"Factory Serial Num" and "Serial Num" are listed under "Chassis/WWN Unit 1" and "Chassis/WWN Unit 2". If the
current WWN cards are the original cards, the factory serial number listed is the same as the chassis serial number.
For example output from the
chassisShow
6. Create a SAN profile by entering and recording the information provided by the following commands:
•
fabricShow
•
nsAllShow
•
nsShow
•
switchShow -qsfp
Copy the command output into a text file named "SANbefor.txt." After the device is restored to the fabric, this
information can be used to verify that no unintentional changes have occurred to the fabric.
switch:admin> nsshow
Enter Pid COS PortName NodeName TTL
<output truncated>
switch:admin> nsallshow
12 Nx_Ports in the Fabric
<output truncated>
switch:admin> switchshow
switchName: switch
53-1004105-13