53-1005235-09 Installation Guide
Brocade
®
G630 Switch Hardware Installation Guide
Figure 30: Nonport-Side LEDs with AC Power Supplies
1. Power Supply Unit 2 OK LED
2. Power Supply Unit 2 FAIL LED
3. Power Supply Unit 1 OK LED
4. Power Supply Unit 1 FAIL LED
5. Fan Assembly Unit 1 Status LED
6. Fan Assembly Unit 2 Status LED
7. Fan Assembly Unit 3 Status LED
Power Supply OK and FAIL Status LEDs
Use the following table to interpret the power supply status LEDs during normal operation.
Table 18: Power Supply Status LEDs during Normal Operation
OK LED
FAIL LED
Description
Action Required
Off
Off
No AC power to all the power supplies.
No action is required.
Off
Blinking amber
Power supply continues to operate but is experiencing
high temperature, high power, or a slow fan.
Check and replace the power supply
unit before it fails completely.
Off
Steady amber
Power supply unit failed due to overvoltage, overcurrent,
overtemperature, or fan failure.
Check and replace the power supply
unit.
Slow-blinking
green
Off
AC is applied to the power supply unit, and standby
voltage is available.
No action is required.
Steady green
Off
Power supply is on and running normally.
No action is required.
Fan Assembly Status LED
Use the following table to interpret the fan assembly status LED during normal operation.
53-1005235-09