53-1005235-09 Installation Guide
Brocade
®
G630 Switch Hardware Installation Guide
•
Intake power supply and fan assembly with an orange "I" label or without any label
: Pulls air from the nonport
side of the switch and exhausts it out the port side.
•
Nonport-side air intake
•
Port-side air exhaust
•
Back-to-front (nonport-side to port-side) airflow
•
Part numbers ending with -R
•
Exhaust power supply and fan assembly with a green "E" label
: Pulls air from the port side of the switch and
exhausts it out the nonport side.
•
Nonport-side air exhaust
•
Port-side air intake
•
Front-to-back (port-side to nonport-side) airflow
•
Part numbers ending with -F
Power Supply Assembly Fault Indicators
Use one of the following methods to determine the status of the power supply assemblies:
•
Check the power supply OK and FAIL status LEDs. See
Power Supply OK and FAIL Status LEDs
meaning of LED operation.
•
In Web Tools, click the
Power Status
icon.
•
Enter the
psShow
command at the prompt to display power supply assembly status, as shown in the following
example:
Device:admin> psshow
Power Supply #1 is OK
Power Supply #2 is OK
Power Supply Assembly Task Guide
You can perform an easy set of steps to install or replace a power supply assembly or to replace both power supply
assemblies. By default, the power supply assemblies are installed in the device.
Installing an Additional Power Supply (Hot-Install)
If your device is up and running with a single power supply assembly and you want to install an extra power supply,
complete the following steps:
1. Insert the new power supply assembly.
2. Plug in the power cord to the power supply assembly and the power source.
3. Turn on the power source.
4. Verify the power supply assembly OK and FAIL status LEDs.
53-1005235-09