Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
Enable (1)
Enable hot plug power feature.
Configure
51
Pri. Port SMB Address (ASF/IPMI)
Description:
SMB address of the primary port on a device.
Configure
52
Sec. Port SMB Address (IPMI)
Description:
SMB address of the secondary port on a device (only valid for dual port devices).
Configure
53
Cable Sense
Description:
Enables a low power mode (IDDQ) of the chip which allows the presence of a cable to be
detected by the chip (valid for 5752M/5755M/5787M/5787FM devices). Once Cable Sense
is enabled GPIO3 will be an Energy Detect Output Pin and will be high if a cable (with a
signal present) is plugged into the RJ45 and low otherwise.
Disable (0)
Disable cable sense.
Enable (1)
Enable cable sense.
Configure
54
GPIO 0 Input/Output Config
Description:
Setting GPIO 0 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0)
Config as input
Output HI (1)
Config as output HI
Output LO (2)
Config as output LOW
Configure
55
GPIO 2 Input/Output Config
Description:
Setting GPIO 2 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0)
Config as input
Output HI (1)
Config as output HI
Output LO (2)
Config as output LOW
Configure
56
L1ASPM Debounce En
Description:
Enable L1ASPM Debounce for PCI-E Mobile Devices only
Disable(0)
Disable
Enable (1)
Enable
Example: (For Selfboot firmware).
0:>secfg
1. MAC Address.........: 001018000000
2. Device Id...........: 1693
3. Sub Vendor Id.......: 14E4
4. Sub Device Id.......: 1693
5. Wake on LAN.........: Disabled
6. WoL Speed Limit 10..: Disabled
7. LOM/NIC design......: NIC
8. Phy. Auto PowerDown.: Disabled
9. Reverse Nway........: Disabled
a. Disable PowerSaving.: Disabled
b. LED mode............: Phy1 Mode
page 50
Broadcom Confidential and Proprietary