Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
This test can to be configured by running “diagcfg”. See “diagcfg” for details. If a “test
list” is not entered below then a set of default tests are run.
Syntax:
nictest [test list]
abcd -- runs all tests
b -- runs all test in group B
a3 b1 -- runs test a3 and b1 only
a124b2 -- runs test a1,a2,a4 and b2
Options:
-e
run NVRAM verification also
-n<DEC>
iteration
10.112 intrtest
cmd:
intrtest
Description:
Interrupt Test
Syntax:
intrtest [iteration]
Options:
-n<DEC> iteration (The default iteration is 1. 0 means run forever.)
10.113 pkttest
Command:
pkttest
Description
: Perform MAC and/or PHY loopback test. This test will send 100 packets in
incremental length and check for contents of loopbacked packets.
Syntax:
pkttest [<iteration>]
Options:
-e
run external loopback test
-m
run mac loopback test
-n<DEC>
iteration (The default iteration is 1. 0 means run forever.)
-p
run phy loopback test
page 103