Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
Options:
-d
Display Present Size Programmed Into NVRAM
-D
Specify [NVRAM] & [TPM] size in decimal (dflt. hex)
10.197 aspm
cmd:
aspm
Description:
Configure the PCI-E Link power state operation at the root complex and the
device under test. Power state option described below.
0 ASPM disable
s ASPM L0s enabled
1 ASPM L1 enabled
a ASPM L0s and L1 enabled
Syntax:
aspm [-e 0|s|1|a] [-r 0|s|1|a] [-x 0|1] [-d] [-i]
Options:
-r<string> Configure root complex device
-e<string> Configure endpoint (Broadcom) device (dut)
-x<DEC> Enable ExtendedSync mode for root complex and endpoint (def=0)
-d Display present ASPM State
-i Ignore all previous ASPM setting after a chip reset
10.198 dids
cmd:
dids
Description:
The feature outputs the following information: PCI DID, VID, SDID &
SVID; MAC address, Firmware revision, PXE, PXESpd, WOL, ASF, MBA, Bond Rev.
This information can be used to verify the setup of a chip after a firmware upgrade.
Syntax:
dids
10.199 serial
cmd:
serial
Description:
Compares the serial number to defaults or the provided values. This PCI
capability testing is only applicable to Shasta C stepping (i.e. BCM5752Cx) family.
Syntax:
serial <dwordLo> <dwordHi>
page 131
Broadcom Confidential and Proprietary